Skip to content

A Comparison of Two Type of Stems in Revision Hip Arthroplasty

A Randomized Controlled Trial Comparing a Titanium to a Cobalt Chrome Femoral Stem in Revision Hip Arthroplasty: A Pilot Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00253838
Enrollment
39
Registered
2005-11-15
Start date
2001-10-31
Completion date
2012-03-31
Last updated
2017-09-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hip Arthroplasty

Keywords

revision hip arthroplasty, bone mineral density

Brief summary

This study compares two different hip stem components. Both hip stems used in this study allow the femur bone to attach and grow into them for stability. The main difference between the two stems is that one of the stems, the Solution® Stem, is made from Cobalt Chrome, a type of metal, and does not have a hydroxylapatite (HA) coating, while the second stem included in the study, the Restoration hip stem, is made from titanium alloy, a different type of metal that has a roughened surface and allows for a hydroxylapatite (HA) coating to be applied to the entire length of the stem. The HA coating is a thin calcium phosphate layer on the stem to encourage the bone to grow into it. We are trying to see if there is any difference in the initial bony ingrowth between the two stems and to compare the results in patients over the first two years after the surgery and then again at the five-year period.

Detailed description

Revision total hip arthroplasty is becoming increasingly common due to the large number of primary total hip arthroplasties being performed annually. Failure of these arthroplasties has led to an increasing number of patients requiring revision arthroplasty. Various methods have been used to reconstruct the hip during a revision procedure. These have generally consisted of a cemented or uncemented femoral stem. It is now generally accepted that uncemented femoral stems have improved results over cemented stems, especially in those cases with compromised bone stock. There are two main alloys used for the femoral revision component, that is cobalt chrome and titanium. There may be certain advantages to the use of titanium, in particular, a reduction in future bone loss caused by stress shielding. Stress shielding is commonly seen with cobalt chrome implants. In order to assess this and the overall survival of these two different implants a randomized clinical trial is proposed.

Interventions

PROCEDURERestoration HA stem

The Restoration hip stem, is made from titanium alloy, a different type of metal that has a roughened surfacing and allows for a hydroxylapatite (HA) coating to be applied to the entire length of the stem.

PROCEDURESolution stem

The Solution stem is made from Cobalt Chrome, a type of metal, and does not have a hydroxylapatite (HA) coating.

Sponsors

Stryker Nordic
CollaboratorINDUSTRY
Ottawa Hospital Research Institute
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Candidates for revision hip arthropathy

Exclusion criteria

* Under 21 years of age

Design outcomes

Primary

MeasureTime frameDescription
Safety of surgical implant24 monthsSafety of surgical implant will be assessed by reviewing revision rates and complication rates post surgery

Secondary

MeasureTime frameDescription
Patient outcome measurespre-op, 6, 12, 24, 60 monthsPatient outcome measures will be assessed using the SF-12 and WOMAC questionnaires.
Effectiveness of surgical implant24 monthsThe Harris Hip Score will be used to evaluate the effectiveness of the surgical implant

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026