Skip to content

Clinical Evaluation of a Wireless Monitoring Device to Reduce Falls in the Elderly and Others at High Risk of Falling

NIH-NIA SBIR Phase I/II Study: Clinical Evaluation of a Device to Reduce Patient Falls

Status
Completed
Phases
Phase 1Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00249743
Enrollment
50
Registered
2005-11-07
Start date
2004-12-31
Completion date
2005-07-31
Last updated
2006-05-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Accidental Falls, Fractures, Injuries

Keywords

fall prevention, fall risk management, RCT, cost

Brief summary

Falls are a public health problem of significant social and economic significance. No primary intervention devices have been shown to be effective in reducing falls and associated injuries. The objective of this study was to determine whether the new wireless FallSaver device reduces falls and fall-related injuries in elderly skilled nursing facility (SNF) residents. A randomized, prospective, open-label, cross-over study was conducted over a six-month period. The FallSaver device reduced the frequency of falls by 50% and fall-related injuries by 82% in 43 elderly at-risk SNF residents studied over 4,222 patient-days. The device and associated patch enclosure was well tolerated and devoid of serious problems. Significant cost savings and fewer reductions in quality of life are possible if fall-related injuries can be reduced.

Detailed description

OBJECTIVE. No existing devices have proven effective in preventing falls in at-risk individuals. The objective of this study was to determine whether the FallSaver device reduces falls and fall-related injuries in elderly skilled nursing facility (SNF) residents. DESIGN. This was a randomized, prospective, open-label, cross-over study conducted over a six-month period. SETTING: The study took place in a 100-bed State Veterans SNF in Washington State. PARTICIPANTS. Forty-four subjects with anticipated institutional stays of at least 120 days participated in the study. The subjects' mean age was 82.2 + 7.1 years and all were rated high fall risks using the Morse scale. INTERVENTION Subjects were randomly assigned to the FallSaver device or no device (Observation) for 60 days. Following the end of the 60-day period subjects were crossed over to the opposite treatment. The device, enclosed in an adhesive patch, was applied to the subject's thigh. MAIN OUTCOME MEASURE The primary outcome measures were falls and fall-related injuries. Secondary outcomes were falls resulting from documented attempts to stand or ambulate without assistance, skin-tolerance to the patch, and compliance. RESULTS. Total patient-days for the FallSaver and Observation phases were 1,923 and 2,299, respectively. A total of 37 falls occurred in 18 subjects. Thirteen falls occurred during the FallSaver phase and 24 during Observation (p = \< 0.05). A total of 7 fall-related injuries occurred; one during the FallSaver phase and 6 during Observation (p = \< 0.01). Nineteen falls resulted from documented attempts to stand or ambulate without assistance, six during the FallSaver phase and 13 during Observation (p = \< 0.05). The patch was well tolerated and no serious adverse effects were observed. CONCLUSION. The FallSaver device reduced the frequency of falls by 50% and fall-related injuries by 82% in elderly at-risk SNF residents. The device and associated patch enclosure was well tolerated and devoid of serious problems. Significant cost savings and fewer reductions in quality of life are possible if fall-related injuries can be reduced.

Interventions

DEVICEFallSaver (formerly called NOCwatch)

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
National Institute on Aging (NIA)
CollaboratorNIH
NOCwatch International
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
0 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Residents of a skilled nursing facility. An anticipated institutional stay of at least 120 days. Individuals with a high risk of falling according to the Morse scale (a score of 55+).

Exclusion criteria

* Individuals who were allowed to self-ambulate. Individuals with a history of adverse reactions to medical adhesives. Individuals with a history or presence of significant skin breakdown on the legs.

Design outcomes

Primary

MeasureTime frame
Falls and fall-related injuries.

Secondary

MeasureTime frame
Falls resulting from documented attempts to stand or ambulate without assistance.
Skin tolerance to the adhesive.
Compliance.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026