3-D Transcranial Ultrasound Analysis Study

3-D Transcranial Ultrasound Analysis Using Definity Injectable Suspension

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00239525
Acronym
Definity
Enrollment
28
Registered
2005-10-17
Start date
2006-05-31
Completion date
2013-12-31
Last updated
2014-04-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cerebrovascular Accident, Intracranial Hypertension

Keywords

Cerebrovascular Accident, Intracranial Hypertension

Brief summary

The purpose of this study is to investigate real time 3-D ultrasound imaging of the brain for the diagnosis and evaluation of stroke.

Detailed description

The objective of this proposal is to extend our previous advances to investigate real time 3-D ultrasound imaging of the brain for the diagnosis and evaluation of stroke. Over the last decade, with the availability of color flow Doppler combined with effective ultrasound contrast agents, a renaissance has occurred in transcranial sonography as a low cost, bedside method for evaluation and management of patients with cerebrovascular disease in spite of the image degrading properties of the skull. Our hypothesis is that we can combine new generations of 2D array transducers with ultrasound contrast agents and phase aberration correction to enable real time 3D ultrasound imaging and 3D color flow Doppler of the brain with a factor of 10 improvement in spatial resolution compared to conventional transcranial sonography for improved diagnosis and evaluation of stroke.

Interventions

DEVICE3-D ultrasound scanner

The availability of color flow Doppler combined with effective ultrasound contrast agents in transcranial sonography serves as a low cost, bedside method for evaluation and management of patients with cerebrovascular disease in spite of the image degrading properties of the skull.

DRUGPerflutren Protein-Type A Microspheres for injection

Activated DEFINITY® (Perflutren Lipid Microsphere) Injectable Suspension is indicated for use in patients with suboptimal echocardiograms to opacify the left ventricular chamber and to improve the delineation of the left ventricular endocardial border.Bolus: The recommended dose for activated DEFINITY® is 10 microliters (μL)/kg of the activated product by intravenous bolus injection within 30-60 seconds, followed by a 10 mL saline flush. If necessary, a second 10 microliters (μL)/kg dose followed by a second 10 mL saline flush may be administered 30 minutes after the first injection to prolong contrast enhancement. Infusion: The recommended dose for activated DEFINITY® is via an IV infusion of 1.3 mL added to 50 mL of preservative-free saline. The rate of infusion should be initiated at 4.0 mL/minute, but titrated as necessary to achieve optimal image enhancement, not to exceed 10 mL/minute.

Sponsors

Duke University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Exclusion criteria

* persons \<18 years old * pregnant or nursing women * history of neurological disease * congenital heart defect * severe liver dysfunction * respiratory distress syndrome * hypersensitivity or an allergic reaction to blood products.

Design outcomes

Primary

MeasureTime frameDescription
Phase aberration correction of skull bone6 monthsThis study will look to improve adaptive signal processing techniques for phase aberration correction of the skull while incorporating ultrasound contrast agent to increase signal to noise ratio in an ultrasound B-scan system with high speed RF data acquisition and 2-D arrays.In addition,we hope to develop adaptive transcranial real time 3D ultrasound and real time 3D color flow Doppler scanning of the brain incorporating ultrasound contrast agent to increase signal to noise ratio. A clinical evaluation of adaptive transcranial ultrasound imaging of the brain with phase aberration correction and ultrasound contrast agent will be conducted.

Countries

United States

Outcome results

None listed