Skip to content

The BRIDGE Registry: Safety and Efficacy Registry of Bx Cypher Stent

Safety and Efficacy Registry of Bx Cypher Stent in the Revascularisation of Patients With Significant Risk of Restenosis

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00232804
Enrollment
639
Registered
2005-10-05
Start date
2002-06-30
Completion date
2004-02-29
Last updated
2007-10-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

The objective of this study is to establish the safety and efficacy of the treatment with Cypher DES in diabetic patients with documented ischemia due to stenosis (small coronary artery 2.5 -3 mm in lumen diameter, with lesion between 15 mm 30 mm in length, ) in native coronary arteries. The objective of this study is to document that the use of Cypher DES in these diabetic patients undergoing percutaneous revascularization for stenosis is safe. Safety will be assessed over a period of 12 months.

Detailed description

This is a prospective, multicenter, comparative, non randomised, open registry of 1000 patients who will be followed up to 12 months at 100 sites in France. Patients will be screened according to normal practice and in relation to the inclusion and exclusion criteria. Patients should have a documented ischemia related to the target vessel. Procedure of stent placement should be done under existing in hospital procedural protocol and care should be taken to follow Cordis instructions as set forth in the Instructions For Use. Follow up will be done according to normal procedure and the minimum should be a telephone contact at 1, 6 and 12 months. All data gathered during the enrollment, procedure, follow up and when specific events to the patient may occur, will be entered into the Internet CRF form, by the treating physician or a person from his staff specifically appointed to this task. Patient enrollment is anticipated to last 8 months.

Interventions

DEVICEBx Cypher stent

Sponsors

Cordis US Corp.
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. NIDDM treated with oral antidiabetics for at least 3 months, or IDDM treated for at least 3 months with documented HbA1C; 2. Diagnosis of angina pectoris as defined by Canadian Cardiovascular Society Classification (CCS I, II, III, IV) OR unstable angina pectoris (Braunwald Classification B I-II) OR patients with documented silent ischemia; 3. Target lesion stenosis is \>50% (visual estimate); 4. Target vessel diameter, between 2.5 and 3.0 mm 5. Target lesion length minimum 15 mm and maximum 30mm

Exclusion criteria

1. CK and CK-MB enzymes above normal or elevated troponin level (as determined by site criteria) at the time of treatment; 2. Has unstable angina classified as Braunwald III B and A or C I-II-III, or is having a peri-infarction; 3. Unprotected left main coronary disease with \>=50% stenosis; 4. Significant (\>50%) stenosis proximal or distal to the target lesion that might impede inflow or runoff and can not be revascularized before or during the index procedure; 5. Have an ostial target lesion; 6. Documented left ventricular ejection fraction \<=30%; 7. In-Stent restenosis; 8. Chronic total occlusion.

Design outcomes

Primary

MeasureTime frame
MACE.1, 6, and 12 months post-procedure

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026