Skip to content

SPIRIT FIRST Clinical Trial of the Abbott Vascular XIENCE V® Everolimus Eluting Coronary Stent System

SPIRIT First: A Clinical Evaluation of an Investigational Device. The Abbott XIENCE V® Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions

Status
Completed
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00180453
Enrollment
60
Registered
2005-09-16
Start date
2003-12-31
Completion date
2009-06-30
Last updated
2010-01-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease, Coronary Artery Stenosis, Everolimus, Myocardial Ischemia, Vascular Disease

Keywords

Cardiovascular disease, Ischemia

Brief summary

Prospective, randomized, controlled, single-blinded, parallel two-arm, multicenter trial. Test arm: XIENCE V® Everolimus Eluting Coronary Stent System(stent length: 18mm, diameter: 3.0mm) Control arm: Metallic stent (MULTI-LINK VISION® metallic stent(stent length: 18mm, diameter: 3.0mm) Follow-up angiographic imaging and intra vascular ultra sound (IVUS) at 180 days and 1 year

Detailed description

The SPIRIT FIRST clinical trial will enroll approximately 60 patients and will assess the feasibility and performance of the XIENCE V® Everolimus Eluting Coronary Stent System in the treatment of patients with de novo native coronary artery lesions. In this trial, the XIENCE V® Everolimus Eluting Coronary Stent System will be compared to the MULTI-LINK VISION® metallic stent which is CE marked and FDA approved and is available for commercial use in Europe and in the United States. The SPIRIT FIRST Clinical trial will enroll approximately 60 patients (30 patients in the test arm and 30 patients in the control arm) with de novo native coronary artery lesions in 4 clinical sites in The Netherlands and Germany

Interventions

DEVICECoronary artery drug eluting stent placement

Coronary artery drug eluting stent placement

DEVICECoronary artery stent placement

Coronary artery stent placement

Sponsors

Abbott Medical Devices
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient must be at least 18 years of age. 2. Patient is able to verbally acknowledge an understanding of the associated risks, benefits and treatment alternatives of receiving the XIENCE™ V Everolimus Eluting Coronary Stent System and his or her legally authorized representative provides written informed consent prior to the stent procedure, as approved by the appropriate Ethics Committee. 3. Patient must have evidence of myocardial ischemia (e.g., stable or unstable angina, silent ischemia, positive functional study). 4. Patient must be an acceptable candidate for coronary artery bypass graft (CABG) surgery. 5. Patient must agree to undergo all protocol-required follow-up examinations including angiographic and IVUS follow-up at two time points (180 days and 1 year ). 6. Female patients of childbearing potential must have had a negative pregnancy test within 7 days before treatment, and must not be nursing at the time of treatment. 7. Female patients of childbearing potential must also agree at time of consent to use birth control up to and including the second angiographic follow-up at 1 year. Inclusion Criteria: Angiographic 1. Planned single, de novo, type A - B1, native coronary artery lesion treatment. 2. Target lesion must be located in a native vessel with a diameter of 3.0 mm assessed by QCA on-line. 3. Target lesion length ≤ 12 mm, assessed by QCA on-line. 4. The target lesion must be in a major artery or branch with a stenosis of ≥ 50% and \< 100% assessed by QCA on-line and with a TIMI flow of ≥ 1.

Exclusion criteria

1. Patient has had a known acute myocardial infarction (greater than two times the upper limit of normal CK with presence of CK-MB) within 3 days preceding the index procedure and CK has not returned to normal limits at the time of the procedure. 2. Patient has current or a history of unstable arrhythmias, regardless of whether cardiac rhythm management devices are used (e.g., pacemaker, Automatic Implantable Cardioverter Defibrillator). 3. Patient has a known left ventricular ejection fraction ≥ 30%. 4. Patient has received a heart transplant or any other organ transplant or is on a waiting list for any organ transplant. 5. Patient is receiving or scheduled to receive chemotherapy or radiation therapy within 30 days prior to or after the procedure. 6. Patient is receiving immunosuppression therapy or has known immunosuppressive disease. 7. Patient is receiving chronic anticoagulation therapy (e.g., heparin, coumadin). 8. Patient has a known hypersensitivity or contraindication to aspirin, heparin, clopidogrel, cobalt, chromium, nickel, tungsten, everolimus, acrylic and fluoro polymers or contrast sensitivity that cannot be adequately pre-medicated. 9. Patient has a platelet count \<100,000 cells/mm3 or \>700,000 cells/mm3, a WBC of \<3,000 cells/mm3, or documented or suspected liver disease (including laboratory evidence of hepatitis). 10. Patient has known renal insufficiency (e.g., serum creatinine level of more than 2.5 mg/dL, patient on dialysis). 11. Patient has a history of bleeding diathesis or coagulopathy or will refuse blood transfusions. 12. Patient has had a cerebrovascular accident (CVA) or stroke or transient ischemic neurological attack (TIA) within the past six months. 13. Patient has had a significant GI or urinary bleed within the past six months. 14. Patient has extensive peripheral vascular disease that precludes safe 6 French sheath insertion or extreme anticoagulation. 15. Patient has other medical illness (e.g., cancer or congestive heart failure) or recent history of substance abuse that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e., less than one year). 16. Patient is already participating in another investigational use device or drug study or has completed the follow-up phase of another trial within the last 30 days. 17. Patient has received a drug eluting stent within the last 1 year.

Design outcomes

Primary

MeasureTime frame
In-stent late lossat 180 days post procedure

Secondary

MeasureTime frame
In-segment Late Lossat 180 days and 1 year
In-stent and in-segment %Volume Obstructionat 180 days and 1 year
In-stent and in-segment %Diameter Stenosisat 180 days and 1 year
In-stent and in-segment Angiographic Binary Restenosis rateat 180 days and 1 year
In-stent late lossat 1 year post procedure
Major Adverse Cardiac Eventsat 30, 180, 270 days, and 1, 2, 3, 4, 5 years
Target Vessel Failureat 30, 180, 270 days, and 1, 2, 3, 4, 5 years
Acute success (device, procedure and clinical)Acute
Persisting incomplete apposition, late incomplete apposition, aneurysm, thrombus, persisting dissectionat 180 days and 1 year

Countries

Denmark, Germany, Netherlands

Outcome results

None listed