LEAF - Low Energy In Atrial Fibrillation

Low Energy in Atrial Fibrillation AF Phase IV Study in AT/AF Population Atrial Arrhythmias Prevention and Reduction With Low Energy Atrial Antitachycardia Pacemaker

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00157781
Enrollment
237
Registered
2005-09-12
Start date
2000-08-31
Completion date
2003-11-30
Last updated
2025-07-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation, Atrial Tachyarrhythmia

Keywords

Atrial Fibrillation, Atrial Tachyarrhythmia, Pacing, Electrophysiology

Brief summary

The purpose of the study is to demonstrate the efficiency on AT / AF prevention and termination of a new algorithm contained in the Medtronic AT500 Antitachycardia device in patients with conventional pacemaker indications.

Detailed description

Aim. More than 30% of patients (pts) implanted with a pacemaker are known to have atrial tachyarrhythmias (AT) despite medical treatment and about 20% of pts experience AT prior to implant. The Medtronic AT500TM is a new DDDRP pacemaker with extended memory and features designed for preventing and terminating AT. The objective of this European multi-center prospective crossover and randomized study is to evaluate efficacy of this device for decreasing AT burden, improving QOL and reducing symptoms and costs. Method. 243 pts are implanted with the AT500TM and followed at 1, 7 and 13 months after implant. All patients are selected for a dual chamber pacemaker indication plus at least two episodes of AT in the last 12 months. One month after implantation patients are randomized either to a six month therapy phase (activation of preventive and ATP pacing) or a six month observation phase (No AT prevention nor Therapy). Crossover (CO) takes place at seven months after implant and the endpoint is reached at 13 months. Symptom checklist and QOL questionnaires are completed by pts at enrollment and after the two randomization periods. At each follow-up, a Save to Disk (STD) of device-stored AT episodes is performed and hospitalization, visits and/or other examinations are reported for future cost evaluation.

Interventions

DEVICEMedtronic AT500

Sponsors

Medtronic
CollaboratorINDUSTRY
Medtronic Cardiac Rhythm and Heart Failure
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* ACC/AHA Class I or II indication for dual chamber pacing and two symptomatic atrial fibrillation or flutter episodes in the three months prior to implant as well as ECG documentation of at least one episode in the prior year.

Exclusion criteria

* Patients with permanent/persistent AF, an indication for an implantable cardioverter defibrillator or class IV heart failure.

Design outcomes

Primary

MeasureTime frame
Demonstrate that AT 500 algorithms decrease AF Burden

Secondary

MeasureTime frame
Characterize the efficiency of prevention and termination algorithms on the Quality of Life of patients
Characterize the correlation between symptoms and stored EGM's
Determine the total number of AF/AT episodes and observe the decrement of their occurrence frequency due to prevention algorithms.
Determine the number of Hospitalization, physician visits…: economical analyze
Analyze the episode onset mechanism