Influence of Mechanical Stimulus on Distraction Osteogenesis

Influence of Mechanical Stimulus on Distraction Osteogenesis

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00154856
Enrollment
10
Registered
2005-09-12
Start date
2004-08-31
Completion date
2005-07-31
Last updated
2005-09-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Leg Discrepancy

Keywords

osteogenesis, Ilizarov fixator, motion analysis, FEM, bone stress

Brief summary

a further step of our current one-year NSC project, aiming to bridge the above-mentioned gap by continuously monitoring the mechanical stimuli applied to the limb and callus, both through experimental measurements and FEM calculations, and by correlating the observed quantity and quality of the mechanical stimuli with the calculated stress and strain patterns of the callus tissue.

Detailed description

Bone lengthening using distraction osteogenesis has found many clinical applications in the treatment of limb length discrepancies, limb deformities, bone defects and fracture nonunion. Animal studies have shown that mechanical conditions significantly affect the biological process of osteogenesis. Knowledge of the influence of mechanical stimuli on the formation of bone is thus essential for the improvement of the current technique, contributing to the treatment and care of patients receiving bone lengthening. Previous in vivo human studies have approached the problem by measuring the interfragmentary movement of bone fracture and the loading in the limb in terms of the ground reaction forces. The mechanical environment in the callus is not available with these approaches. As the stress and strain behavior of bone is critical to its normal function, the response to bone osteotomy and osteogenesis, a limited number of studies have used simplified FEM technique to examine the strain and stress patterns in the callus in two dimensions during simplified loading conditions. The calculated strain patterns, however, can be far from the real situation in the callus. No data are available for the stress and strain patterns during the process of distraction osteogenesis. The present study is a further step of our current one-year NSC project, aiming to bridge the above-mentioned gap by continuously monitoring the mechanical stimuli applied to the limb and callus, both through experimental measurements and FEM calculations, and by correlating the observed quantity and quality of the mechanical stimuli with the calculated stress and strain patterns of the callus tissue. Specifically, in this proposed study, 3D finite element models of the osteogenesis at four temporal points during the limb lengthening process for each subject will be developed from CT data of the osteotomy sites. A 3D model of the musculoskeletal model of the lower limb will be used to calculate the forces transmitted by the bone and surrounding tissues, which will be used for subsequent FEM analysis. The purpose of the study is to determine the stress and strain patterns in the callus at different distraction stages and, with the data collected from gait laboratory experiments performed in our current NSC project, to provide a clearer picture of the influence of mechanical stimuli on distraction osteogenesis. It is hoped that the present study will lead to a better understanding of the mechanisms of osteogenesis, which will be helpful in finding appropriate fixation methods in distraction osteogenesis that optimize the mechanical environment for bone formation.

Interventions

BEHAVIORALDetect the variation of limb lengthening

Sponsors

National Science and Technology Council, Taiwan
CollaboratorOTHER_GOV
National Taiwan University Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
0 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Leg differences above 3cm

Exclusion criteria

\-

Design outcomes

Primary

MeasureTime frame
Leg Length

Countries

Taiwan

Outcome results

None listed