Skip to content

Dual Chamber Versus Single Chamber Cardiac Pacing in People 80 Years of Age and Older

Pacing the Octogenarian Plus Population (POPP) A Comparison of Physiologic Versus Ventricular Pacing in Those Who Are 80 Years of Age and Older

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00116987
Enrollment
800
Registered
2005-07-01
Start date
2003-08-31
Completion date
2009-11-30
Last updated
2015-06-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation, Cardiac Pacing, Artificial

Keywords

physiologic pacing, ventricular pacing, hospitalizations

Brief summary

Of the 19,000 pacemakers implanted across Canada in 2002, 1/3 of them were for patients 80 years and older. This is the fastest growing segment of our population, yet no study has specifically been done in this age group to determine the optimal pacing mode. We wish to determine whether dual chamber or single chamber pacing is associated with a reduction in emergency room visits or hospitalizations for cardiovascular causes (e.g., congestive heart failure (CHF), atrial fibrillation (AF)) resulting in improved quality of life.

Detailed description

Many patients who are 80 years of age and older, develop AF or CHF. Physiologic pacing has been shown to prevent AF compared to ventricular pacing. Whether prevention of AF and CHF by physiologic pacing reduces emergency room visits or hospitalizations for cardiovascular causes in this population in unknown. The investigators wish to determine the optimal pacing mode for this patient population that would enable optimal management of cardiovascular problems, resulting in improved quality of life and minimizing use of health care facilities. Patients recruited to the study will be randomized to either DDDR or VVIR pacing, and followed in the clinic every 6 months for the 3 years of the study.

Interventions

DEVICEDual chamber cardiac pacemaker

Physiologic pacemakers usually have two leads - one positioned in the right atrium (upper heart chamber) and one positioned in the right ventricle.

DEVICESingle chamber cardiac pacemaker

Ventricular pacemakers have a single lead (wire) positioned in the right ventricle (lower pumping chamber) to sense and pace the ventricle.

Sponsors

Calgary Health Trust
CollaboratorOTHER
University of Calgary
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
80 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 80 years of age and older * Symptomatic bradycardia

Exclusion criteria

* Permanent atrial fibrillation * Previous pacemaker implant * Life expectancy less than 1 year * Geographic isolation * Unable to give informed consent

Design outcomes

Primary

MeasureTime frame
To determine which pacing mode, physiologic or ventricular, is associated with a reduction in emergency room visits or hospitalizations for cardiovascular/cerebrovascular causesapproximately 3 - 5 years

Secondary

MeasureTime frame
To determine which pacing mode, physiologic or ventricular, is associated with improved functional capacity and improved quality of lifeapproximately 3 - 5 years

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026