Skip to content

Transcranial Magnetic Stimulation (TMS) and Obsessive Compulsive Disorder (OCD)

Treatment of Obsessive Compulsive Disorder (OCD) With Transcranial Magnetic Stimulation (TMS)

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00106249
Enrollment
27
Registered
2005-03-22
Start date
2004-11-30
Completion date
2014-01-31
Last updated
2017-01-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Obsessive-Compulsive Disorder

Keywords

TMS, Supplementary Motor Area, Obsessive-Compulsive Disorder

Brief summary

This study will evaluate the clinical efficacy of functional Magnetic Resonance Imaging (fMRI) guided 1 Hz repetitive Transcranial Magnetic Stimulation (rTMS) applied to the Supplementary Motor Area (SMA) in OCD patients who have not fully responded to conventional therapies. The investigators will collect TMS measures of motor cortex excitability to test whether rTMS restores normal levels of intracortical inhibition found to be deficient in OCD. The investigators hypothesize that: 1. Compared to sham (placebo), active rTMS will improve symptoms of OCD as assessed with the Yale Brown Obsessive Compulsive Scale (Y-BOCS) and Clinical Global Impression (CGI). 2. Active (but not sham) rTMS will normalize levels of motor cortex excitability, as reflected by increased intracortical inhibition, motor threshold, and cortical silent period, and by decreased intracortical facilitation, relative to pre-treatment baseline.

Detailed description

This study tests the efficacy of functional Magnetic Resonance Imaging (fMRI) guided repetitive Transcranial Magnetic Stimulation (rTMS) in the treatment of Obsessive Compulsive Disorder (OCD). This study also examines measures of brain function that may inform us about the brain basis underlying OCD. Despite major advances in the study and treatment of OCD, patients often do not respond or experience only partial remission from pharmacotherapy or cognitive behavioral therapy. rTMS is a non-invasive procedure that allows stimulation of the brain using magnetic fields. Some studies have reported that rTMS may be helpful in reducing obsessive and compulsive symptoms. While promising, prior research has several limitations (e.g., relatively small sample sizes, stimulation of sub-optimal target areas, relatively short durations of treatment, and lack of sham (placebo) comparison). This study addresses the drawbacks of prior work, and will provide data that will be important in determining whether rTMS can be useful for OCD patients resistant to conventional therapies. In this trial, 32 adult outpatients with OCD, that have been only partially responsive to conventional therapies, will be randomly assigned to one of two treatment groups (active low frequency (1 Hz) rTMS or sham-placebo) applied to the Supplementary Motor Area (SMA) daily for up to four weeks. If rTMS will be added onto ongoing pharmacotherapy, the doses must have been stable for 3 months prior to study entry. The SMA was selected because of its connections with areas of the brain, especially motor areas, implicated in OCD. Pilot work indicates that stimulation of SMA with low frequency rTMS was beneficial in OCD patients. Low frequency rTMS has the added benefit of a better safety profile (i.e. no risk of seizure) compared to high frequency rTMS. Rating scales for symptom change will be obtained at baseline, during the rTMS course, and at the end of 4 weeks of treatment. Patients who do not meet response criteria after four weeks of sham and partial responders to either active or sham will be offered an open-label, cross-over phase for an additional four weeks of daily active rTMS treatment. Patients who meet response criteria in either the randomized phase or the cross-over phase will continue routine clinical care under the supervision of their treating psychiatrist, and will be invited back for a repeat assessment at 3 and 6 months to determine the persistence of benefit. Measures of the excitability of the motor cortex have been reported to be abnormal in OCD, and may relate to dysfunction in motor pathways related to OCD circuits. We will collect measures of motor cortex excitability (performed with single pulse TMS) at baseline and after treatment to determine whether changes in these measures may be correlated with clinical improvement.

Interventions

DEVICERepetitive Transcranial Magnetic Stimulation (rTMS)

Stimulus train of 30 min duration, 1Hz frequency, and 110% of the motor threshold intensity given once a day, 5 days a week, for 4 weeks by Magstim SuperRapid Magnetic Stimulator.

DEVICESham

Sham rTMS will be administered using the Magstim Sham coil which contains a mu-metal shield that diverts the majority of the magnetic flux such that a minimal (less than 3%) magnetic field is delivered to the cortex in order to provoke a subjective sensation similar to that obtained with the real stimulation but without inducing significant cortical stimulation.

Sponsors

New York State Psychiatric Institute
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* Primary diagnosis of obsessive compulsive disorder, with residual OCD symptoms, defined as a total Y-BOCS score of ≥ 16, despite treatment with an adequate trial of a serotonin reuptake inhibitor (SRI), and a duration of the index episode of at least a year will be included. An adequate SRI trial is defined as treatment for at least 12 weeks on the SRI, that meets or exceeds the recommended dosage level for OCD (fluoxetine 60 mg/d, sertraline 200 mg/d, paroxetine 50 mg/d, fluvoxamine 250 mg/d, citalopram 60 mg/d, escitalopram 30 mg/d). * Individuals who cannot tolerate medications of class and dose at the specified duration as described above will also be included. * Patients currently on OCD medication must be at the same stable dose(s) and must continue to be under the care of their treating psychiatrist who will be writing prescriptions for concomitant medications through the duration of the study.

Exclusion criteria

* Refractory patients, where treatment refractoriness is defined as non-response to Clomipramine, at least 2 SSRIs at adequate dose and duration plus cognitive behavior therapy in the last year, will be excluded. An adequate trial of cognitive behavioral therapy is defined as at least once a week for 8 weeks with clear evidence of exposure during the sessions and homework given. Individuals diagnosed with major depressive disorder (current) of moderate or severe intensity (CGI ≥ 4), and those with bipolar disorder (lifetime), any psychotic disorder (lifetime), history of substance abuse or dependence within the past year (except nicotine and caffeine), and at significant acute suicide risk will also be excluded. Other

Design outcomes

Primary

MeasureTime frameDescription
Clinical Improvement (Yale-Brown Obsessive Compulsive Scale/Y-BOCS)Through study completionResponse rate was defined as a decrease \>25% on the YBOCS-SR. Y-BOCS-Self Report (Baer et al. 1993) is very similar to the clinician-administered one, and has shown excellent internal consistency and test-retest reliability, performing somewhat better than the interview (Steketee et al., 1996); subjects are asked to focus on the main obsessions and main compulsions and to answer five questions: time spent, interference, distress, resistance, and control. Consistent with the interview format, subjects rate each item on a 0 (none) to 4 (extreme) scale.

Secondary

MeasureTime frameDescription
Motor Cortex Excitability (Motor Threshold)Through study completionIn 22 OCD patients, who completed the RCT, we applied the new customized software for acquisition and analysis of neurophysiology data that was developed to allow for automatic control of the TMS devices during motor cortex excitability measures. Specifically, the software delivers TMS pulses and automatically determines motor threshold (MT); a descending staircase method is utilized, starting at the intensity at which the optimal site selection for the MT is determined. After each stimulus in the MT experiments, the software would prompt the user to confirm the automated MEP-detection.
Motor Cortex Excitability (Short Intracortical Inhibition)Through study completionIn 22 OCD patients enrolled in the RCT, we applied the new customized software for acquisition and analysis of neurophysiology data that was developed to allow for automatic control of the TMS devices during motor cortex excitability measures. For the paired-pulse (PP) measurements of short intracortical inhibition (SICI) the interstimulus interval (ISI) was set to 8-12 seconds on a continuous uniform distribution. The FPGA board samples the EMG data, controls the timing of the TMS stimuli, and also controls the intensity of the devices.

Countries

United States

Participant flow

Participants by arm

ArmCount
Active rTMS
Active Repetitive Transcranial Magnetic Stimulation (rTMS) Repetitive Transcranial Magnetic Stimulation (rTMS): Stimulus train of 30 min duration, 1Hz frequency, and 110% of the motor threshold intensity given once a day, 5 days a week, for 4 weeks by Magstim SuperRapid Magnetic Stimulator.
14
Sham rTMS
Placebo Repetitive Transcranial Magnetic Stimulation (rTMS) Sham: Sham rTMS will be administered using the Magstim Sham coil which contains a mu-metal shield that diverts the majority of the magnetic flux such that a minimal (less than 3%) magnetic field is delivered to the cortex in order to provoke a subjective sensation similar to that obtained with the real stimulation but without inducing significant cortical stimulation.
13
Total27

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyLost to Follow-up32

Baseline characteristics

CharacteristicActive rTMSSham rTMSTotal
Age, Continuous40.1 years
STANDARD_DEVIATION 13.1
37.1 years
STANDARD_DEVIATION 11.8
38.6 years
STANDARD_DEVIATION 12.5
Gender
Female
5 Participants5 Participants10 Participants
Gender
Male
9 Participants8 Participants17 Participants
Region of Enrollment
United States
14 participants13 participants27 participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 110 / 11
serious
Total, serious adverse events
0 / 110 / 11

Outcome results

Primary

Clinical Improvement (Yale-Brown Obsessive Compulsive Scale/Y-BOCS)

Response rate was defined as a decrease \>25% on the YBOCS-SR. Y-BOCS-Self Report (Baer et al. 1993) is very similar to the clinician-administered one, and has shown excellent internal consistency and test-retest reliability, performing somewhat better than the interview (Steketee et al., 1996); subjects are asked to focus on the main obsessions and main compulsions and to answer five questions: time spent, interference, distress, resistance, and control. Consistent with the interview format, subjects rate each item on a 0 (none) to 4 (extreme) scale.

Time frame: Through study completion

ArmMeasureValue (NUMBER)
Active rTMSClinical Improvement (Yale-Brown Obsessive Compulsive Scale/Y-BOCS)36 percentage of participants
Sham rTMSClinical Improvement (Yale-Brown Obsessive Compulsive Scale/Y-BOCS)9 percentage of participants
p-value: <0.05ANOVA
Secondary

Motor Cortex Excitability (Motor Threshold)

In 22 OCD patients, who completed the RCT, we applied the new customized software for acquisition and analysis of neurophysiology data that was developed to allow for automatic control of the TMS devices during motor cortex excitability measures. Specifically, the software delivers TMS pulses and automatically determines motor threshold (MT); a descending staircase method is utilized, starting at the intensity at which the optimal site selection for the MT is determined. After each stimulus in the MT experiments, the software would prompt the user to confirm the automated MEP-detection.

Time frame: Through study completion

Population: repeated measure ANOVA, time X group interaction, right hemisphere MT

ArmMeasureValue (MEAN)
Active rTMSMotor Cortex Excitability (Motor Threshold)13 % MT change on right hemisphere
Sham rTMSMotor Cortex Excitability (Motor Threshold)0 % MT change on right hemisphere
p-value: <0.05t-test, 2 sided
Secondary

Motor Cortex Excitability (Short Intracortical Inhibition)

In 22 OCD patients enrolled in the RCT, we applied the new customized software for acquisition and analysis of neurophysiology data that was developed to allow for automatic control of the TMS devices during motor cortex excitability measures. For the paired-pulse (PP) measurements of short intracortical inhibition (SICI) the interstimulus interval (ISI) was set to 8-12 seconds on a continuous uniform distribution. The FPGA board samples the EMG data, controls the timing of the TMS stimuli, and also controls the intensity of the devices.

Time frame: Through study completion

Population: Independent sample t-test, right hemisphere SICI

ArmMeasureValue (MEAN)
Active rTMSMotor Cortex Excitability (Short Intracortical Inhibition)2.5 % change in conditioned/control MEP
Sham rTMSMotor Cortex Excitability (Short Intracortical Inhibition)1 % change in conditioned/control MEP

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026