Research on the usefulness of patch-type continuous blood glucose meters in ICU

Research on the usefulness of patch-type continuous blood glucose meters in ICU

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-jRCTs042230176
Enrollment
100
Registered
2024-03-21
Start date
2024-03-21
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypoglycemia Hyperglycemia Hypoglycemia ,Hyperglycemia

Interventions

Before and after entering the intensive care unit, a continuous blood glucose meter will be attached to the patient, and blood sugar levels will be continuously measured until the patient leaves the i

Sponsors

Kuwabara Takahiro
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients admitted to the intensive care unit who are 18 years of age or older Patients with an arterial line inserted Patients who understand the research content and have obtained written consent from themselves or their families

Exclusion criteria

Exclusion criteria: Patients under 18 years old Patients who do not have an arterial line inserted or have difficulty collecting blood from an arterial line Patients using other implanted medical devices such as pacemakers Patients who are judged to be unsuitable for participation in this study by the principal investigator or co-investigator

Design outcomes

Primary

MeasureTime frame
Correlation between the blood glucose level obtained by the first central blood sampling after admission to the intensive care unit and the blood glucose level measured by a continuous blood glucose meter at the time of the first central blood sampling

Secondary

MeasureTime frame
Correlation between the blood glucose level measured by the first central blood sampling after admission to the intensive care unit and the blood glucose level measured by a continuous blood glucose meter at the time of the first central blood sampling in diabetic patients Correlation between the blood glucose level measured by the first central blood sampling after admission to the intensive care unit and the blood glucose level measured by a continuous blood glucose meter at the time of the first central blood sampling in non-diabetic patients Correlation between the blood sugar level measured by the initial arterial blood gas test using ABL-800 and the blood sugar level measured by a continuous blood glucose meter at the same time (all cases, diabetic cases, non-diabetic cases) Correlation between the blood glucose level at the initial arterial blood gas test by EPOC and the blood glucose level at the same time using a continuous blood glucose meter (all cases, diabetic cases, non-diabetic cases) Correlation between the initial blood glucose level measured using a simple blood glucose meter using arterial blood and the blood glucose level measured at the same time using a continuous blood glucose meter (all cases, diabetic cases, non-diabetic cases) Comparison of blood glucose levels obtained by arterial blood gas testing using ABL-800 (routine measurement every 4 hours) and blood glucose levels obtained using a continuous blood glucose meter at the same time Comparison of blood glucose levels obtained by EPOC arterial blood gas tests (routine measurements every 4 hours) and blood glucose levels measured using a continuous blood glucose meter at the same time. Percentage of blood glucose outside the acceptable range (70-180 mg/dL) in arterial blood gas tests using ABL-800 (routine measurements every 4 hours, until discharge from the intensive care unit) (compared with historical control) Percentage of blood glucose outside the acceptable range (70-180 mg/dL) in a

Contacts

Public ContactTakahiro Kuwabara

Nagoya University School of Medicine Hospital

kuwa0525bara@gmail.com+81-52-744-2340

Outcome results

None listed