Skip to content

Accuracy of quantification of myocardial blood flow by Dynamic Stress Perfusion CT: verification with 15O-H2O PET

Accuracy of quantification of myocardial blood flow by Dynamic Stress Perfusion CT: verification with 15O-H2O PET - ACCEPTOP trial

Status
Active, not recruiting
Phases
Phase 3
Study type
Interventional
Source
JPRN
Registry ID
JPRN-jRCTs042220045
Enrollment
47
Registered
2022-07-15
Start date
2024-01-09
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Known or suspected chronic coronary artery disease Chronic coronary artery disease

Interventions

Myocardial perfusion CT examinations for clinical purposes are currently performed using a Siemens CT system (SOMATOM FORCE) at Mie University Hospital. This is due to the fact that there have been ma
D055414
Myocardial Perfusion Imaging

Sponsors

Ichikawa Yasutaka
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1) Patients with known or suspected chronic coronary artery disease who are clinically indicated to be evaluated by myocardial perfusion imaging 2) Age 50-75 3) Patients who have given written consent to perform 15O-H2O myocardial perfusion PET and to participate in the study

Exclusion criteria

Exclusion criteria: 1) Contraindications to adenosine triphosphate and iodine contrast media 2) Claustrophobia that makes it difficult to perform cardiac PET and CT examinations 3) Difficulty with breath holding required for the cardiac PET and CT examinations 4) Poor general condition 5) Women with known or possible pregnancy 6) Inappropriate research participants (judged by the researchers in this study) 7) Patients who experienced a cardiovascular event, underwent revascularization, or had a change or addition of medication between cardiac CT and myocardial perfusion PET examinations 8) Reduced renal function (determined as eGFR less than 0.45 mL/min/1.73m2 within 1 month before the examinations) 9) A past history of myocardial infarction

Design outcomes

Primary

MeasureTime frame
The purpose of the study in the pilot group was to examine whether there were systematic errors (Pearson's correlation coefficient greater than 0.5) in myocardial blood flow measurements (segment-based and patient-based) between stress CTP and 15O-H2O myocardial perfusion PET, and to compute the correction equation if the systemic error is found. The validity of the correction equation will be evaluated using the intraclass correlation coefficient in the validation group.

Secondary

MeasureTime frame
1. Regional and global hyperemic myocardial blood flow and myocardial blood flow reserve (ratio of blood flow during vasodilator stress to at rest) determined from cardiac CT are compared with myocardial blood flow reserve determined from 15O-H2O myocardial blood flow PET. 2. In patients undergoing invasive coronary angiography, the diagnostic value of myocardial blood flow measured with cardiac CT will be evaluated for detecting significant coronary stenosis and significant abnormalities in Fractional Flow Reserve (FFR) and Instantaneous Wave-Free Ratio (iFR). 3. Evaluation of morphological features of the distribution of myocardial ischemic regions on perfusion CT.

Contacts

Public ContactYasutaka Ichikawa

Mie University Hospital

yasutaka@med.mie-u.ac.jp+81-59-231-5029

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026