Skip to content

Magnetically-guided capsule panendoscopy for gastrointestinal tumors (MagCam study)

Randoimized sham-controlled comparative study on prospective and retrospective detecatability of magnetically-guided capsule panendoscopy for gastrointestinal tumors (MagCam study)

Status
Active, not recruiting
Phases
Phase 2
Study type
Interventional
Source
JPRN
Registry ID
JPRN-jRCTs042180150
Enrollment
100
Registered
2019-03-29
Start date
2019-04-01
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

carcinoma of esophagus,gastric tumor,large intestine tumor

Interventions

carcinoma of esophagus,gastric tumor, large intestine tumor

Sponsors

Ohmiya Naoki
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1. The patient that a document agreement by the free will of the person was provided on enough understanding after having received enough explanation on participating of this study 2. Patients younger than 80 years 20 years old or older at the time of the agreement acquisition

Exclusion criteria

Exclusion criteria: 1.dysphagia 2.A patient with the past of the allergic reaction to a drug to use in the final examination 3.A woman who I am pregnant or may become pregnant 4.A patient that an examination of MRI is planned within two weeks after a capsule endoscope 5.Patient having a symptom to let you doubt a gastrointestinal stenosis 6.Patient having the progress cancer of the esophagus with stenosis, stomach cancer, colon cancer 7. Patient with a history of the abdominal radiation exposure 8.Having a pacemaker or defibrillator 9.When it is inappropriate

Design outcomes

Primary

MeasureTime frame
1.Depiction ability of the capsule endoscope according to having magnetic induction or not for known gastrointestinal tumor 2.Depiction ability of the capsule endoscope according to the presence of the magnetic induction for the unknown lesion of the part unlike a known gastrointestinal tumor

Secondary

MeasureTime frame
1.Inspection time for all gastrointestinal capsule endoscopes according to having magnetic induction or not 2.Quantity of pre-treatment, booster of all gastrointestinal capsule endoscopes according to having magnetic induction or not 3.Patient satisfaction of all gastrointestinal capsule endoscopes according to having magnetic induction or not 4.It is an emergency phenomenon after the inspection of all gastrointestinal capsule endoscopes according to having magnetic induction or not, inspection

Contacts

Public ContactMasashi Kondo

Fujita Health University

mkond@fujita-hu.ac.jp+81-562-93-9362

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026