Skip to content

A Multicenter, Single-arm, Confirmatory Study to Assess the Safety and Efficacy of Intracranial Cerebral Aneurysm Embolization with G-009

A Multicenter, Single-arm, Confirmatory Study to Assess the Safety and Efficacy of Intracranial Cerebral Aneurysm Embolization with G-009 - G-009-P01

Status
Active, not recruiting
Phases
Phase 3
Study type
Interventional
Source
JPRN
Registry ID
JPRN-jRCT2052210121
Enrollment
39
Registered
2021-11-12
Start date
2021-12-16
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Unruptured cerebral aneurysm Cerebral Aneurysm

Interventions

At least two antiplatelets (aspirin, clopidogrel, cilostazol, ticlopidine, etc.) should be administered as pre-medication from 4 days or more before to the day of the index procedure. The test device
D002532
Cerebral aneurysm embolization, Covered stent

Sponsors

Ueno Junji
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1) Has a single unruptured aneurysm located in the internal carotid artery, intradural vertebral artery, or basilar artery that requires treatment. 2) The aneurysm is difficult to treat with conventional surgical treatment. 3) Has an aneurysm with any of the following morphologies: - Wide-neck aneurysm with a maximum diameter of 10mm or more - Aneurysm with a maximum diameter of 5 mm or more and less than 10 mm, which is likely to recur with conventional treatments (cerebral aneurysm coil embolization, stent-assisted coil embolization) - Spindle-shaped aneurysm 4) Has a degree of independence in the daily life corresponding to modified Rankin Scale 3 or less. 5) Provided voluntary written consent to participate in this clinical trial. 6) Is willing to perform follow-up visits at 30 days, 90 days, 6 months, and 12 months after the procedure 7) Has a parent vessel into which the test device can be navigated.

Exclusion criteria

Exclusion criteria: 1) Has an posterior circulation aneurysm with any of the following morphologies: - The test device would be implanted across the basilar artery bifurcation - Large or giant dolichoectatic aneurysm 2) The aneurysm is located at the bifurcation of the cerebral artery. 3) A major branch is located on the dome of the cerebral aneurysm. 4) Has another cerebral aneurysm, other than the target aneurysm, that needs to be treated simultaneously. 5) Has an anatomical structure that is not suitable for endovascular treatment (severe tortuosity, stenosis). 6) Has a mycotic or dissecting aneurysm. 7) Has a history of stent placement in the target aneurysm.

Design outcomes

Primary

MeasureTime frame
Efficacy: Percentage of subjects with complete occlusion of the target aneurysm and a patent parent vessel (luminal stenosis rate 50% or less) as evaluated by angiography at 12 months who did not receive retreatment for the target aneurysm within 12 months after the procedure. Safety: Percentage of subjects who experienced the following events 1) or 2): 1) Death or major stroke within 30 days after the procedure 2) Cranial nerve-related death or ipsilateral major stroke within 12 months after the procedure

Secondary

MeasureTime frame
Efficacy: 1) Percentage of subjects who have an occlusion of 90% or more with a patent parent vessel (luminal stenosis of 50% or less) as evaluated by angiography at 12 months who did not receive retreatment for the target aneurysm within 12 months after the procedure. 2) Percentage of subjects who have an occlusion of 90% or more as evaluated by angiography at 12 months after the procedure. 3) Percentage of subjects who have a patent parent vessel (luminal stenosis rate 50% or less) as evaluated by angiography at 12 months after the procedure. 4) Percentage of subjects who did not receive retreatment for the target aneurysm within 12 months after the procedure. 5) Evaluation of the degree of embolization of the target aneurysm and changes over time at 6 months and 12 months after the procedure (to be completed in subjects who underwent angiography at 6 months after the procedure). 6) Technical success rate (percentage of subjects who had a stent placed in the parent vessel including the aneurysm neck and a patent parent vessel at the end of the procedure). 7) Incidence of stent migration at 12 months after the procedure. Safety: 1) Incidence of cranial nerve-related death up to 12 months after the procedure. 2) Incidence of stroke or death up to 12 months after procedure. 3) Percentage of subjects with a higher mRS score on neurological evaluation at 6 months and at 12 months after the procedure (as compared to the baseline). 4) Incidence of serious adverse events for which a causal relationship with the test device or procedure cannot be ruled out. 5) Incidence of device failures.

Contacts

Public ContactYusuke Takahata

GOODMAN CO., LTD.

yusuke.takahata@goodmankk.com+81-3-5919-3229

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026