Skip to content

COVID-CP Banking

Establishment of COVID-19 Convalescent Plasma Banking System in Japan - COVID-CP Banking

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-jRCT1030200279
Enrollment
100
Registered
2020-12-25
Start date
2020-12-25
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

coronavirus disease 2019 COVID19 Plasma therapy Biobank Biobanking

Interventions

Plasma of a person who has recovered from infection and who is negative for the new coronavirus (SARS-CoV-2) and has a high neutralizing antibody titer should be collected using a component blood samp
COVID-19, Convalescent Plasma

Sponsors

Tanosaki Ryuji
Lead Sponsor
Saya Hideyuki
Collaborator

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: (1) Blood type (ABO, Rh type) and irregular antibody are negative (Keio University Hospital) (2) The following infectious disease screening antigen antibody test is negative or within the blood donation standard range: syphilis serological test, hepatitis B virus test (HBs antigen, HBs antibody, HBc antibody), hepatitis C virus test (HCV antibody) ), HIV test (HIV-1, 2 antibody), HTLV-1 antibody test, human parvovirus test, nucleic acid amplification test (HBV, HCV, HIV) (when antibody test of each virus becomes positive) (consigned to Nisseki And carry out) (3) SARS-CoV-2 neutralizing antibody titer (conducted at National Institute of Infectious Diseases Toyama Government Building) is high titer positive (1: 160 or more is a guide). (4) SARS-CoV-2 blood PCR (conducted at the National Institute of Infectious Diseases Murayama Government Building) is negative.

Exclusion criteria

Exclusion criteria: 1) A clinically meaningful irregular antibody becomes positive, 2) The infectious disease screening is positive or out of the blood donation standard range. 3) SARS-CoV-2 neutralizing antibody titer was judged to be low (1:80 or less is a guideline. Since the criteria are not sufficiently standardized, it will be decided in consultation with the National Institute of Infectious Diseases) 4) SARS-CoV-2 PCR is positive 5) The person in charge of business determines that it is inappropriate

Design outcomes

Primary

MeasureTime frame
Safety of COVID-19 CP donor

Secondary

MeasureTime frame
Feasibility of COVID-19 CP Banking