Skip to content

An Exploratory Clinical Trial of Low-Frequency Therapy for Cardiac Sarcoidosis

An Exploratory Clinical Trial of Low-Frequency Therapy for Cardiac Sarcoidosis

Status
Active, not recruiting
Phases
Phase 2
Study type
Interventional
Source
JPRN
Registry ID
JPRN-jRCT1012260003
Enrollment
30
Registered
2026-04-20
Start date
2026-04-20
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac sarcoidosis Sarcoidosis, Cardiac sarcoidosis

Interventions

A low-frequency stimulation device will be attached to the auricle, and stimulation will be administered once daily for 1 hour, using 1.5 mA, 25 Hz, and 250 us as the standard settings.
D011846

Sponsors

Nagai Toshiyuki
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients meeting all of the following criteria will be eligible for inclusion: 1. Individuals aged 18 years or older at the time informed consent is obtained. 2. Individuals diagnosed with cardiac sarcoidosis in accordance with the Japanese Circulation Society Guidelines for the Diagnosis and Treatment of Cardiac Sarcoidosis (2016 edition), including those with an implanted pacemaker or implantable cardioverter-defibrillator (ICD). 3. Individuals who, after receiving a full explanation regarding participation in this study, are able to actively comprehend the written informed consent document and from whom written informed consent has been obtained based on their own free will.

Exclusion criteria

Exclusion criteria: Patients meeting any of the following criteria will be excluded from the study: 1. Individuals with a history of progressive brain lesions. 2. Individuals receiving vagus nerve stimulation therapy. 3. Individuals with a history of severe cardiovascular disease. 4. Individuals with a history of hypersensitivity to glycerin. 5. Individuals who are pregnant or breastfeeding. 6. Individuals with skin hypersensitivity and a history of developing skin symptoms caused by metals or similar materials. 7. Individuals with difficulty taking food or medications orally. 8. Individuals with a history of dementia. 9. Individuals using a cardiac pacemaker or implantable cardioverter-defibrillator (ICD) that does not conform to ISO 14117. 10. Individuals otherwise deemed inappropriate for participation in the study by the Principal Investigator or a Sub-Investigator.

Design outcomes

Primary

MeasureTime frame
1. Number and duration of arrhythmic events per day, as assessed by Holter electrocardiography and pacemaker interrogation. 2. Echocardiographic parameters, including left ventricular ejection fraction. 3. Parameters assessed by 18F-FDG PET/CT, including FDG uptake. 4. Biomarkers. 5. Occurrence of death during low-frequency therapy. 6. Correlation between inflammation before and after low-frequency therapy and the expression of pathological factors.

Contacts

Public ContactAkinori Takahashi

Faculty of Medicine and Graduate School of Medicine, Hokkaido University

aki.highbridge528@gmail.com+81-11-706-6973

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026