Skip to content

The Effect of Non-Invasive Continuous Blood Pressure Monitoring on Attenuating Blood Pressure Fluctuations during Anesthesia Induction

The Effect of Non-Invasive Continuous Blood Pressure Monitoring on Attenuating Blood Pressure Fluctuations during Anesthesia Induction

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-jRCT1012250037
Enrollment
24
Registered
2025-10-02
Start date
2025-10-02
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

General anesthesia

Interventions

Place an oscillometric automated blood pressure cuff on one arm and a VitaWave Finger Cuff on the contralateral hand to continuously measure blood pressure. Anesthesiologists will manage blood pressur

Sponsors

Hayamizu Kengo
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients aged 65 years or older scheduled to undergo general anesthesia for surgery

Exclusion criteria

Exclusion criteria: Patients scheduled for invasive arterial blood pressure monitoring Patients with difficulty in finger cuff placement due to finger abnormalities or deformities Patients with a history of finger injuries, dermatitis, soft tissue damage, or fractures Patients with impaired peripheral circulation, including those with Raynaud's disease Patients with a preoperative difference of 10% or more in blood pressure between the left and right upper arms Patients deemed unsuitable for the study by the principal investigator or co-investigators

Design outcomes

Primary

MeasureTime frame
TWA of MAP < 65 mmHg for 20 minutes following the start of anesthesia

Secondary

MeasureTime frame
Incidence of hypotension (MAP < 65 mmHg) after anesthesia induction, time to detection of hypotension, dosage and frequency of vasopressor use, discomfort during device placement and measurement, and presence of complications.

Contacts

Public ContactKengo Hayamizu

Sapporo Medical University

k.hayamizu@sapmed.ac.jp+81-11-688-9663

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026