A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled study

A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled study - A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled study

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-UMIN000053918
Enrollment
44
Registered
2024-03-20
Start date
2024-04-22
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patients with upper gastrointestinal, lower gastrointestinal, hepatobiliary, gynecologic, or urologic diseases undergoing laparoscopic surgery in the 0 degrees pronation in both upper limb position

Interventions

The electromyography electrode, NM-345Y, is attached such that the line connecting the centers of the anode and cathode of the stimulating electrode crosses the ulnar nerve. The NM-345Y is placed as d

Sponsors

Nagasaki University Hospital
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Age: 18 years old or older Surgery: Laparoscopic surgery in the 0 degrees pronation position of both upper limbs Diseases: Upper gastrointestinal, lower gastrointestinal, hepatobiliary, gynecologic, or urologic diseases

Exclusion criteria

Exclusion criteria: Patients who already have neurological disorders (e.g., paralysis) Patients with neuromuscular diseases Patients with pacemakers or implantable cardioverter defibrillators Pregnant women Patients with fragile skin where the electromyography electrode seal is attached Patients with a history of surgery on the measuring limb Patients with a history of allergy to rocuronium or sugammadex Patients undergoing hemodialysis Patients undergoing robot-assisted laparoscopic surgery

Design outcomes

Primary

MeasureTime frame
Time to the appearance of the first post-tetanic count (PTC) after the first rocuronium administration

Secondary

MeasureTime frame
The stimulus current value and sensitivity at calibration, time to the appearance of the first train-of-four (TOF) count after the first rocuronium administration, total PTC counts every two hours after positional change, time to the appearance of the TOF counts one, two, three, and four after the last rocuronium administration, the TOF counts or the TOF ratio and the amplitudes of T1 before and after sugammadex administration, time to the TOF ratio greater than 0.9 after sugammadex administration