Skip to content

Evaluation of the accuracy of the blood pressure values measured by pressurized and decompressed oscillometric devices in hypertensive patients with specific complications

Evaluation of the accuracy of the blood pressure values measured by pressurized and decompressed oscillometric devices in hypertensive patients with specific complications - Evaluation of the accuracy of the blood pressure values measured by pressurized and decompressed oscillometric devices in hypertensive patients with specific complications

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-UMIN000053071
Enrollment
200
Registered
2023-12-14
Start date
2023-12-14
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypertension, diabetes, chronic kidney disease (CKD), heart failure, history of atherosclerotic cardiovascular disease (ASCVD: stroke, myocardial infarction, angina pectoris, aortic dissection, peripheral vascular disease)

Interventions

Blood pressure measurements are taken 14 times in the sitting position, up to a maximum of 20 times. The measurement procedure consists of two auscultation measurements, followed by three sets of tes

Sponsors

Jichi Medical University School of Medicine
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients who meet all the following criteria will be eligible for this study. 1) Upper arm circumference: 22.0-42.0cm 2) Age at the time of consent >= 20 years old 3) Consent to participate in this study was obtained [Composition of subjects] 1) At least 40 subjects aged 65 years and over 2) At least 40 hypertensive patients each with the following complications: diabetes*1, CKD*2, heart failure, history of ASCVD (however, patients with multiple complications may be enrolled, in which case they will be included in the number of patients with each disease). 3) At least 40 hypertensive patients without any complications of the diseases listed in 2) *1: HbA1c >= 6.5 % or medicated diabetes mellitus *2: eGFR < 60 mL/min/1.73 m2 or urinary protein (+) or higher

Exclusion criteria

Exclusion criteria: Patients with upper arm injuries that cannot be worn with a cuff Patients with arrhythmia Pregnant women

Design outcomes

Primary

MeasureTime frame
Consistency of the blood pressure values measured by a pressurized or decompressed oscillometric BP monitoring device and by an auscultatory method

Secondary

MeasureTime frame
- Systolic BP and diastolic BP in each method - Measurement error relative to reference (auscultation value) - Measurement error relative to reference (auscultation value) in each disease group - BP waveforms and shapes in each disease group