Skip to content

A phase II study of Simultaneous integrated boost intensity modulated radiotherapy using volumetric modulated arc therapy for locally advanced lung cancers and thoracic malignancies

A phase II study of Simultaneous integrated boost intensity modulated radiotherapy using volumetric modulated arc therapy for locally advanced lung cancers and thoracic malignancies - Simultaneous integrated boost intensity modulated radiotherapy using volumetric modulated arc therapy for locally advanced lung cancers and thoracic malignancies

Status
Active, not recruiting
Phases
Phase 2
Study type
Interventional
Source
JPRN
Registry ID
JPRN-UMIN000041875
Enrollment
50
Registered
2021-02-28
Start date
2016-02-06
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Locally advanced non-small cell lung cancer, post-operative recurrence of non-small cell lung cancer

Interventions

Patients recieved SIB-IMRT using VMAT, and total dose was 69Gy and 51Gy in 30 fractions for gross tumor and elective lymph node.

Sponsors

Hyogo College of Medicine
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1) pathologically proven clinical stage-II or III non-small cell lung cancer, or loco-regional recurrence after surgery or chemotherapy, 2) non-surgical candidate, 3) no distant metastasis 4) aged 20 or over, 5) performance status: 0 or 1, 6) A written informed consent was obtained

Exclusion criteria

Exclusion criteria: 1) history of thoracic irradiation 2) with uncontrollable co-morbidity 3) with other active double primary cancer 4) with interstitial pneumonitis or pulmonary fibrosis 5) in pregnant

Design outcomes

Primary

MeasureTime frame
overall survival rate at three years after radiation therapy

Secondary

MeasureTime frame
the progression free survival at three years after radiation therapy, the incidence and degree of radiation pneumonitis, relationship between radiation pneumonitis and dosimetric factors the incidence of adverse effects the validity of re-treatment planning using the DIR software, the validity of adoptive radiation therapy with cone beam CT, determining the optimal re-planning period, the influence of the changes of body contour for the accuracy of IMRT

Countries

Japan

Contacts

Public ContactMasayuki Fujiwara

Hyogo College of Medicine Department of Radiology

m-fuji@hyo-med.ac.jp0798-45-6362

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026