Skip to content

Study on pulmonary function imaging diagnosis by chest X-ray dynamics photographing with motion picture compatible flat panel detector.Application 2 in emergency area: For chest trauma patients.

Study on pulmonary function imaging diagnosis by chest X-ray dynamics photographing with motion picture compatible flat panel detector.Application 2 in emergency area: For chest trauma patients. - Clinical application of chest x-ray dynamic photography 2

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
JPRN
Registry ID
JPRN-UMIN000035010
Enrollment
50
Registered
2018-12-01
Start date
2017-12-01
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chest trauma patients

Interventions

None listed

Sponsors

Fukushima Medical University hospital
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients who are hospitalized at the University Hospital or scheduled to be hospitalized and satisfy the following conditions 1) Be an adult over 20 years old 2) Written informed consent 3) Patients suspected of chest trauma or patients diagnosed with chest trauma 4) Chest CT contrast test scheduled for diagnosis or follow-up of chest trauma

Exclusion criteria

Exclusion criteria: 1) have allergy to the contrast agent 2) During pregnancy, possibility of pregnancy, delivery within 28 days, breast-feeding 3) Psychiatric disorder or psychiatric symptoms are merged and it is judged difficult to participate in the trial 4) Severe cases (during artificial respiration, SpO2 <93% even when administered oxygen, wearing an extracorporeal circulation assisting device, shock index> 1, during noradrenaline administration, GCS <13) 5) Even if it does not apply to 4) above, the patient who judged treatment as priority by the attending physician

Design outcomes

Primary

MeasureTime frame
Sensitivity for diagnosis of pulmonary contusion in measurement method of respiratory variation of permeability of 18 lung fields by chest X-ray dynamic imaging apparatus with contrast CT examination as a reference

Secondary

MeasureTime frame
1. Specificity for diagnosis of pulmonary contusion in measurement method of respiratory variation of permeability of 18 lung fields by chest X-ray dynamic imaging apparatus with contrast CT examination as a reference. 2. Chronological comparison of throat movable range (difference of thoracic area between inspiratory and expiratory) and variation of pixel value in inspiratory and expiratory phase with respiratory function test (%VC, FEV1.0) as references

Countries

Japan

Contacts

Public ContactJIRO SHIMADA

Fukushima Medical University hospital Emergency and Critical Care Center

jshimada3@gmail.com0245471111

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026