Skip to content

A pilot study of a simple navigation system for Total Hip Arthroplasty in the lateral position using augmented reality technology

A pilot study of a simple navigation system for Total Hip Arthroplasty in the lateral position using augmented reality technology - A pilot study of a simple navigation system for Total Hip Arthroplasty in the lateral position using augmented reality technology

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-UMIN000031602
Enrollment
40
Registered
2018-03-06
Start date
2018-01-09
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hip joint disease scheduled for total hip arthroplasty Osteoarthritis, Rheumatoid Arthritis, Femoral head necrosis, Femoral neck fracture, rapidly destructive coxopathy, subchondral insufficiency fracture of the femoral head.

Interventions

Set the target angle in advance, and install the cup using (A)angle goniometer. After installing the cup, Measure installation angle by using (B)simple navigation system using AR technology Set the t

Sponsors

Nissan Tamagawa Hospital
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: (1) Patients who are scheduled to undergo THA with hip joint disease. (2) Patients aged 20 years or older at the time of acquiring consent (4) Document consent can be obtained by the patient's free will, after receiving sufficient explanation for the participation of this study, after understanding

Exclusion criteria

Exclusion criteria: (1) Patients who have been registered in the past in this study (2) Patients judged by the principal investigator to be inappropriate as subjects

Design outcomes

Primary

MeasureTime frame
The Accuracy of Implant Placement using X-ray and CT at 3 months postoperative (Absolute value error between intraoperative measured value and postoperative measured value)

Secondary

MeasureTime frame
Using CT at 3 months after surgery, -Cup installation angle and differences from 3-dimensional preoperative plan (adiographic inclination (RI) and radiographic anteversion (RA)) -Accuracy of leg extension and femoral neck cut level(Absolute value error between intraoperative measured value and postoperative measured value)

Countries

Japan

Contacts

Public ContactHiroyuki Ogawa

Nissan Tamagawa Hospital Department of Orthopaedic Surgery

wscww899@yahoo.co.jp03-3700-1151

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026