Skip to content

Assesment of the body water distribution after esophagectomy using Bioelectrical Impedance Analysis(BIA) device and FloTrac system

Assesment of the body water distribution after esophagectomy using Bioelectrical Impedance Analysis(BIA) device and FloTrac system - Assesment of the body water distribution after esophagectomy using BIA device and FloTrac system

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-UMIN000030734
Enrollment
200
Registered
2018-01-09
Start date
2017-06-01
Completion date
Unknown
Last updated
2026-09-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Esophageal cancer

Interventions

1) Preoperative BIA measurement after admission(~5 minutes). 2) Anaestheologists insert the peripheral arterial catheter during the esophagectomy and connect to the FloTrac system (intraoperative pro

Sponsors

University of Tokyo
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients who meets all of the conditions below are included in the study. 1) Who are to receive esophagectomy for esophageal cancer at University of Tokyo Hospital. 2) Agreed to participate in the study in documents.

Exclusion criteria

Exclusion criteria: Patients who meets any of the conditions below are excluded from the study. 1) Those under 20 years old. 2) Those with heart pacemakers. 3) Those with preoperatively diagnosed heart failure or respiratory failure. 4) Those who cannnot use electrodes for BIA devices due to allergic reactions or dermatological problems. 5) Those who cannot keep the supine position during the measurements due to psychological or other factors. 6) Those who meet the contraindication criteria described in the manuals of BIA device (MLT-550N) or FloTrac system. 7) Those who have ineligibility judged by the researchers of the study.

Design outcomes

Primary

MeasureTime frame
Comparison between the estimated dates of the fluid retention by the traditional judging methods(negative water balance in record-based calculation, decrease in body weight) and the date estimated by the peak in each maker of Bioelectrical Impedance Analysis(BIA) measured on admission day and from postoperative 0 to 7days, or of FloTrac systems measured postoperatively.

Secondary

MeasureTime frame
1) Correlation between the marker trends in BIA or FloTrac system and the trends in blood markers(Hb,Hct,Alb,BUN/Cre,CRP)or urinary osmolarity. 2) Correlation between the postoperative courses (adverse events, length of ICU stay, length of hospital stay) and the levels of BIA or FloTrac markers at postoperative specific timing. 3) Difference in BIA or FloTrac marker peaks among different esophageal surgical procedures.

Countries

Japan

Contacts

Public ContactShuichiro Oya

Graduate School of Medicine, University of Tokyo Gastrointestinal Surgery

OYAS-SUR@h.u-tokyo.ac.jp03-3815-5411

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Sep 19, 2026