Skip to content

Anterior Chamber Angle Measurement with Swept-source Optical Coherence Tomography - A Pilot Normative Database Collection Study

Anterior Chamber Angle Measurement with Swept-source Optical Coherence Tomography - A Pilot Normative Database Collection Study - Anterior Chamber Angle Measurement with SS-OCT

Status
Active, not recruiting
Phases
Unknown
Study type
Unknown
Source
JPRN
Registry ID
JPRN-UMIN000027544
Enrollment
90
Registered
2017-06-01
Start date
2017-06-05
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

healthy subjects, primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma

Interventions

None listed

Sponsors

The Chinese University of Hong Kong
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Japanese healthy subjects and/or patients with primary angle closure glaucoma (PACG) 1. over 40 years 2. eyes not performing cataract surgery 3. maximum visual acuity more than 0.5 4. spherical equivalent (refraction) more than -1.0 diopters Normal eyes always show normal intraocular pressure (from 10 to 21 mmHg), have an open angle, and have no glaucomatous optic neuropathy Glaucoma is an eye with characteristic morphological changes of the optic disc or retinal nerve fiber and corresponding visual field defects PACG is classified as follows according to angular examination and intraocular pressure .primary angle closure suspect(PACS) .primary angle closure (PAC) .primary angle closure glaucoma (PACG)

Exclusion criteria

Exclusion criteria: Those who do not meet inclusion criteria from 1 to 4 Secondary glaucoma, eyes after intraocular surgery including laser treatment, eyes with strong cataract, those who can not conduct reliable examination

Design outcomes

Primary

MeasureTime frame
The scan protocols comprise (1) custom 'Lens biometry' which includes 18 radial B-scans (800 A-scans/B-scan), each with 16 mm in length and 14 mm in depth and (2) 'Anterior segment' which includes 16 radial B-scans (800 A-scans/B-scan), each with 16 mm in length and 11 mm in depth. Eyes will be imaged in the dark (<1.0 lux) for three times with custom 'Lens Biometry' and once with 'Anterior segment'; and then in room light (needs to standardize the room light illumination) for three times with custom 'Lens Biometry' and once with 'Anterior segment'.

Countries

Japan,Asia(except Japan),North America

Contacts

Public ContactRei Sakata

The University of Tokyo hospital Department of ophthalmology

reisakata-tky@umin.ac.jp03-3815-5411

Outcome results

None listed

Source: JPRN (via WHO ICTRP) · Data processed: Jul 3, 2026