Usefulness of intraoperative nerve monitoring in predicting postoperative recurrent laryngeal nerve palsy in esophageal cancer surgery

Usefulness of intraoperative nerve monitoring in predicting postoperative recurrent laryngeal nerve palsy in esophageal cancer surgery - Intraoperative recurrent laryngeal nerve monitoring

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-UMIN000022706
Enrollment
40
Registered
2016-06-12
Start date
2013-10-01
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

esophagealcancer

Interventions

Use of intraoperative nerve monitor The vagus and recurrent laryngeal nerves are stimulated with the current of 1mA for 3 seconds after lymph node dissection

Sponsors

Osaka university
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients who undergo esophagectomy with 3 field lymph node dissection for esophageal cancer

Exclusion criteria

Exclusion criteria: Patients with preoperative recurrent laryngeal nerve palsy

Design outcomes

Primary

MeasureTime frame
The relationship between the amplitude of electromyogram and the occurence of postoperative vocal cord palsy

Secondary

MeasureTime frame
The relationship between the amplitude of electromyogram and the occurence of persistent vocal cord palsy

Countries

Japan

Contacts

Public ContactTakashi Kanemura

Osaka university Surgery

kanemura@tonbyo.org0668793251

Outcome results

None listed