Coronary artery bifurcation disease
Conditions
Interventions
Sponsors
Eligibility
Inclusion criteria
Inclusion criteria: 1)Patient who has a side branch at the stented site and the luminal diameter of the side branch is more than 2mm visually. 2)Patiet with a de novo lesion in which stent will be implanted. 3)Patient who is 20 years of age or older when he/she provides the informed consent.
Exclusion criteria
Exclusion criteria: 1)Patient who has a stent restenosis lesion in which stent will be implanted. 2)Patient with cardiogenic shock. 3)Patient with a chronic total occlusion lesion. 4)Patient with CKD of Cr more than 1.5mg/dl. 5)Patient who is considered not appropriate to undergo PCI. 6)Patient who has any other medical condition that in the opinion of the investigator will not be appropriate to participate in the investigation.
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Post-implant in-stent images obtained via 2D-/3D-OCT will be analyzed to assess the following: 1)Patterns of jailed strut links at side branch site 2)Guide wire recrossing positions into jailed strut 3)Ratio of area of jailed strut cell to area of side branch ostium after dilatation of the side branch 4)Frequency and quantitative evaluation of occurrence of incomplete stent apposition(ISA) | — |
Countries
Japan
Contacts
Osaka Saiseikai Nakatsu Hospital Cardiology