Measurement of normal pharyngeal pressure with High Resolution Manometry System which has 20 circumfeferential pressure sensors.

Measurement of normal pharyngeal pressure with High Resolution Manometry System which has 20 circumfeferential pressure sensors. - Measurement of normal pharyngeal pressure with High Resolution Manometry System.

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
JPRN
Registry ID
JPRN-UMIN000013741
Enrollment
50
Registered
2014-04-16
Start date
2014-04-16
Completion date
Unknown
Last updated
2026-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dysphagia

Interventions

50 Healthy persons 10 times saliva swallowing, 10times of swallowing water 3ml, 10times of swallowing water 5ml, and 10times of swallowing water 10ml. Swallowing of each of which is a continuous e

Sponsors

Department of Otorhinolaryngology, The Jikei University School of Medicine
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Healthy adults

Exclusion criteria

Exclusion criteria: Person with dysphagia Person with foreign body sensation in the throat Person who can not be subject to inspection of using manometry because of gag reflex Person with some sort of ill-health(For example, the common cold, hangover)

Design outcomes

Primary

MeasureTime frame
UES relaxation time. The item mentioned above is evaluated at catheterization.

Secondary

MeasureTime frame
The maximum pressure in the velopharynx and maximum pressure in the meso-hypopharynx were measured during swallowing. The maximum pressure in the UES at the start of the swallowing motion. The minimum pressure after the swallowing motion. The maximum UES pressure after the pressure waveforms in the velopharynx and meso-hypopharynx disappeared. The durations of pressure above baseline in the velopharynx and meso-hypopharynx regions. The time from the point at which the UES pressure started to increase until it reached the maximum pressure at the start of the swallowing motion. The time from when the UES pressure reached the maximum pressure until completion of the gradual decrease, after the waveforms in the velopharynx and meso-hypopharynx disappeared. Change of the measurement values above-mentioned by the amount of volus. The number of the measurement to establish reliable deglutition pressures.