Skip to content

Visual function in patients implanted with Panoptix trifocal intraocular lens

Visual function in pseudophakic patients with bilateral implantation of Acrysof IQ Panoptix Trifocal intraocular lens

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ISRCTN
Registry ID
ISRCTN60143265
Enrollment
50
Registered
2017-04-24
Start date
2016-04-01
Completion date
Unknown
Last updated
2019-02-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataracts Eye Diseases

Interventions

The study recruited over six months and followed each individual patient for one month after undergoing bilateral cataract surgery. Patients were not randomised, the decision to undergo surgery and t
mono- and binocular uncorrected visual acuity in photopic and mesopic conditions, for far, intermediate and near distances
subjective refraction and binocular contrast sensitivity in photopic and mesopic conditions.

Sponsors

Clinica Rementería
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1. Patients over 18 years old 2. Candidates to bilateral cataract surgery 3. Planned bilateral Panoptix intraocular lens implantation

Exclusion criteria

Exclusion criteria: 1. Presence of any ocular pathology which could compromise visual recovery 2. Preoperative astigmatism higher than 1.5 Diopters (D) on corneal topography 3. Abnormal iris 4. Intra- or postoperative complications

Design outcomes

Primary

MeasureTime frame
Mono- and binocular uncorrected visual acuity in photopic and mesopic conditions, for far, intermediate and near distances, measured at 1 month after surgery: 1.1. Distance visual acuity measured using a 22" LED liquid crystal display system (CC-100 HW 5.0 Series, Topcon) that can display ETDRS charts at 4 meters 1.2. Near visual acuity measured using the Logarithmic Visual Acuity Chart 2000 New ETDRS (Precision Vision, Lasalle, IL) at 33 centimeters 1.3. Intermediate visual acuity, measured with the same chart as near acuity (Logarithmic Visual Acuity Chart 2000 New ETDRS (Precision Vision, Lasalle, IL)) and the value adjusted for the 60 centimeter distance For photopic visual acuity measurements, room luminance was 85 candelas [cd]/m2. Mesopic visual acuity measured after dark adaptation (10 minutes in the testing room under mesopic conditions) with the room luminance set to 3 cd/m2

Secondary

MeasureTime frame
1. Subjective refraction, performed with the ETDRS chart at 4 meters 2. The defocus curve, performed monocularly with the patients observing the ETDRS chart through lenses starting at -5.00 D and increasing in 0.50 D steps to +3.00 D 3. Binocular contrast sensitivity, measured at spatial frequencies of 3, 6, 12, and 18 cycles per degree (cpd) using the functional acuity contrast test (Test SV-1000) of the CC-100 HW 5.0 Series system 4. Binocular contrast sensitivity after dark adaptation (10 minutes in the testing room under mesopic conditions), measured at spatial frequencies of 3, 6, 12, and 18 cycles per degree (cpd) using the functional acuity contrast test (Test SV-1000) of the CC-100 HW 5.0 Series system 5. Visual function, assessed using Catquest 9-SF questionnaire Measured at 1 month after surgery

Countries

Spain

Outcome results

None listed

Source: ISRCTN (via WHO ICTRP) · Data processed: Feb 26, 2026