Traditional versus simulation resident surgical laparoscopic salpingectomy training Surgery
Conditions
Interventions
1. The intervention group participated in a training module of assigned pre-session reading on pelvic anatomy from a gynecology textbook and a designated article on ultrasonic energy and a formal 3 ho
reviewed the advanced Bipolar or ultrasonic energy sources used
and a video review of a simulated porcine model laparoscopic salpingectomy performed at our institution. Following this didactic presentation, participants had 60 minutes to familiarize themselves wi
Sponsors
Christiana Care Health System
Eligibility
Sex/Gender
All
Inclusion criteria
Inclusion criteria: All PGY-1 through PGY-4 Ob/Gyn residents at Christiana Care Hospital
Exclusion criteria
Exclusion criteria: Unable to complete OSAT evaluation
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| The primary outcomes are the OSAT scores, based on a multi-item assessment that measures 9 aspects of surgical technique. Each item is rated from 1-5 using a Likert scale where 1 signifies a low and 5 a high score. For this study, the minimum score on the OSAT was 5 and the maximum achievable score was 45. This instrument has acceptable internal reliability (there was a single evaluator) and its validity is supported through correlations with conceptually related measures from a previously validated surgical skills Global Rating Scale. | — |
Secondary
| Measure | Time frame |
|---|---|
| Resident comfort level with laparoscopic surgical salpingectomy | — |
Countries
United States of America
Outcome results
None listed