Skip to content

Occupational health and safety among health care personnel in a COVID-19 pandemic

Predictive value of biological, physiological and analytical biomarkers with the use of personal protection equipment in COVID-19: observational, prospective, analytical, intervention and multicenter study

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ISRCTN
Registry ID
ISRCTN18348009
Enrollment
80
Registered
2020-04-15
Start date
2020-04-16
Completion date
Unknown
Last updated
2023-06-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Complications or secondary effects derived from the use of personal protective equipment against biological risks Not Applicable

Interventions

Volunteers (workers in a COVID19 treatment unit) undergo a structured and objective evaluation. Physiological variables (respiratory rate, saturation, heart rate, systolic and diastolic blood pressure

Sponsors

University of Valladolid
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1. Workers (doctors, nurses and assistants) in the COVID19 treatment unit with the biological risks training course 2. Aged over 18 years 3. Provide informed consent

Exclusion criteria

Exclusion criteria: 1. Pregnant 2. Psychiatric pathology 3. Do not sign the informed consent 4. Not to be part of the HURH and Covid-Fair staff during the month of April

Design outcomes

Primary

MeasureTime frame
1. Respiratory rate, assessed by clinical observation at baseline and at the end of the 4-hour workday 2. Oxygen saturation, assessed using a Physio LifePAK® 15 monitor at baseline and at the end of the 4-hour workday 3. Heart rate, assessed using a Physio LifePAK® 15 monitor at baseline and at the end of the 4-hour workday 4. Blood pressure, assessed using a Physio LifePAK® 15 monitor at the start of the study and at the end of the 4-hour workday 5. Tympanic temperature evaluated using a Braun ThermoScan® PRO 6000 model at baseline and at the end of the 4-hour workday 6. Weight, with the TANITA BC 545-N scale at baseline 8. Size, with the SECA 206 tape measure at baseline 9. Analytical biomarkers: pH, pCO2, pO2, cHCO3-, BE (ecf), cSO2, Na +, K +, Ca ++, Cl-, TCO2, Agap, AGapK, Hct, Hb, BE (b), Glu , Lac, BUN, Urea and Crea, evaluated using COPD Siemens Healthcare at baseline and at the end of the 4-hour workday 10. Medical history of interest, through a structured questionnaire at baseline 11. Level of physical activity using the IPAQ questionnaire at baseline

Secondary

MeasureTime frame
1. Headache presence measured using self-report at the end of the 4 hours of working with the equipment 2. Presence of serious adverse events during the use of protective equipment measured using self-report at the end of the 4 hours of working with the equipment 3. Presence of chafing, wounds, etc., due to the use of protective equipment measured using self-report at the end of the 4 hours of working with the equipment 4. Perception of the state of physical fatigue at the end of the working day with the protective equipment measured using self-report at the end of the 4 hours of working with the equipment 5. Time in COVID19 zone measured using self-report at the end of the 4 hours of working with the equipment

Countries

Spain

Outcome results

None listed

Source: ISRCTN (via WHO ICTRP) · Data processed: Feb 4, 2026