Skip to content

Clinical comparison between a manual suture and a sutureless coupling device (corVCD) connecting the subclavian artery with a 4-finger graft in a complete aortic arch replacement

CLinical comparison bEtween a manual suture and a sutureless coupling device (cOrVCD) coNnecting the subclavian Artery with a 4-finger graft in a complete aortic arch replacement: a RanDOmized controlled study

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ISRCTN
Registry ID
ISRCTN14209306
Enrollment
40
Registered
2013-09-23
Start date
2013-10-01
Completion date
Unknown
Last updated
2018-09-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Vascular diseases like chronic dissections or aneurysms in the area of the aortic arch and the supra-aortic vessels Surgery

Interventions

The aortic arch prosthesis is surgically implanted via a sternotomy under general anesthesia. Initially the aortic arch with its supra-aortic vessels are prepared. The aortic arch prosthesis is made

Sponsors

Corlife OHG (Germany)
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1. Patients with aneurysms (aortic caliber =5.5 cm) or chronic dissections in the area of the aortic arch with indication of an open surgery with an aortic arch prosthesis regarding ACCF/AHA guideline. 2. Patient suitable for operation 3. The patient has opted for an open surgery after deliberating about different available procedures 4. An inner diameter of the Arteria subclavia sinistra of 6.1 to 12.5 mm 5. Serum creatinine = 1.8 mg/dl 6. Estimated life expectancy > 5 years 7. Patient aged 18 to 80 years 8. Written consent form for study participation

Exclusion criteria

Exclusion criteria: 1. Patient cannot undergo an open surgery with circulatory arrest 2. Acute aortic dissection 3. Previous radiation treatment of the target region 4. Local or systemic infections 5. Pre-terminal renal insufficiency (serum creatinine > 1.8 mg/dl) or contrast agent intolerance 6. Conditions in the target region which inhibit an application of prosthetic material 7. Any other life-limiting disease (with an estimated life expectancy < 5 years) 8. Patient age = 18 or = 80 years 9. Pregnancy or lactation 10. Any other disease or medical treatment which interferes with safety or efficacy after assessment of the investigator 11. Patients who are in a dependency relationship or employment with the sponsor or investigator 12. Patients who are unable to give written consent for study participation 13. Concurrent participation in another clinical study 14. Hypersensitivity or allergy against nickel or titanium 15. Hypersensitivity against suture material 16. Absence of a written consent form for study participation

Design outcomes

Primary

MeasureTime frame
The circulatory arrest time of 30± 10 min should be reduced to 20±10 min by the use of corVCD. The verification takes place by time recording.

Secondary

MeasureTime frame
1. With the use of corVCD the time needed to reach a blood-dry anastomosis of the left subclavian artery should be reduced contrary to the application of a conventional suture. The verification takes place by time recording. 2. Potential occurring adverse events (AE) and serious adverse events (SAE) should be less by the use of corVCD in a period of 12 months after surgery.

Countries

Germany

Outcome results

None listed

Source: ISRCTN (via WHO ICTRP) · Data processed: Feb 4, 2026