The Accuracy of Optic Nerve Sheath Diameter Ultrasound in the Diagnosis of Intracranial Hypertension in Children Following Trauma

Evaluation of the Diagnostic Accuracy of Optic Nerve Sheath Diameter (ONSD) Ultrasound in Detecting Increased Intracranial Pressure (ICP) in Children with Head Trauma

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
IRCT
Registry ID
IRCT20250924067353N1
Enrollment
85
Registered
2025-10-24
Start date
2025-11-22
Completion date
Unknown
Last updated
2025-12-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Increased Intracranial Pressure in Children with Head Trauma.

Interventions

This study employs a diagnostic accuracy design and does not involve traditional "intervention" and "control" groups. In this research, all participants (children with head trauma) simultaneously unde

Sponsors

Tabriz University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All
Age
1 Days to 18 Years

Inclusion criteria

Inclusion criteria: Age 0 to 18 years History of head trauma of any severity and mechanism Decision of the attending physician to perform a CT scan based on clinical protocols Obtaining written informed consent from the parent or legal guardian

Exclusion criteria

Exclusion criteria: Eye injuries that interfere with measurement History of eye or optic nerve surgery Neurological or metabolic diseases affecting ICP or ONSD Severe orbital hematomas or fractures that interfere with ultrasound Inability to perform CT scan

Design outcomes

Primary

MeasureTime frame
Optic nerve sheath diameter (ONSD). Timepoint: First visit to the emergency room. Method of measurement: Using ocular ultrasonography The patient is placed in a supine position, and their eyes are kept in a straight-ahead gaze position with closed eyelids. After ensuring the child is calm, a sufficient amount of ultrasound gel is applied to the closed eyelid of each eye.A high-frequency linear probe (in the range of 7.5 to 13 MHz) is then used. The probe is gently placed without applying direct pressure on the eyeball to obtain a suitable longitudinal view of the optic nerve and the optic disc.In the acquired image, the Optic Nerve Sheath Diameter (ONSD) is measured at a distance of 3 mm posterior to the globe, from the point where the optic nerve connects. This measurement is performed by determining the distance between the two reflective, bright (echogenic) lines that mark the inner boundaries of the optic nerve sheath.The measurement is performed separately for each eye, and the average of the two values is recorded as the final Optic Nerve Sheath Diameter.The obtained values are compared to normal ranges based on age. Typically, a diameter of less than 4.5 to 5 mm in children is considered normal, and values higher than this limit may indicate Increased Intracranial Pressure (ICP).

Countries

Iran (Islamic Republic of)

Contacts

Public ContactAmir Hossein Jafari Roohi

Tabriz University of Medical Sciences

jafarirouhi@yahoo.com+98 41 3337 6925