Skip to content

"Effect of Dexmedetomidine in treatment of glaucoma"

Effect of systemic Dexmedetomidine on IOP in patients with refractory hypertensive glaucoma preoperatively

Status
Recruiting
Phases
Phase 3
Study type
Interventional
Source
IRCT
Registry ID
IRCT20230524058280N1
Enrollment
84
Registered
2023-06-28
Start date
2023-06-24
Completion date
Unknown
Last updated
2023-07-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

glaucoma. Glaucoma

Interventions

Intervention 1: Intervention group: The target group is subjected to a slow infusion with a microdrop of 0.5 µg/kg of the intravenous drug dexmedetomidine over fifteen minutes. Intervention 2: Control

Sponsors

Mashhad University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Those who complete the informed consent form Capable of communication Having intraocular pressure (IOP) above 25 mm Hg Those who are resistant to medical treatment and need glaucoma surgery Those with any type of glaucoma, including primary and secondary open-angle and angle-closure glaucoma

Exclusion criteria

Exclusion criteria: Allergy to drugs including the study drug before the intervention Patients with any corneal abnormalities Significant Cardiovascular disease(secondary and tertiary heart block) Congestive heart failure Chronic heart failure and uncontrolled blood pressure BMI above 35 Uncontrolled diabetes mellitus Chronic treatment with Clonidine Liver and renal failure Drug or alcohol abuse Coagulation disorders Pregnancy Patients with antipsychotic and antiepileptic therapy Mental disorders/dementia/deafness/difficulty communicating/inability to lie on back COPD INR above 1.7

Design outcomes

Primary

MeasureTime frame
Intraocular pressure. Timepoint: immediately before the intervention and then five, ten, fifteen and twenty minutes after the intervention. Method of measurement: Tono-Pen AVIA tonometry device by ophthalmologist.

Secondary

MeasureTime frame
Blood pressure. Timepoint: Simultaneously with the measurement of intraocular pressure. Method of measurement: Cardiac monitoring device.;Heart beat. Timepoint: Simultaneously with the measurement of intraocular pressure. Method of measurement: Cardiac monitoring device.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactSeyedMostafa Alavirad

Mashhad University of Medical Sciences

mos77alavi@gmail.com+98 51 3868 5868

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026