Examining breast dose reduction in CT scan with a new combination of x-ray absorbing materials with minimal impact on image quality.

Design and fabrication of radioprotective shield to reduce the radiation dose to the breast in patients undergoing thoracic computed tomography examinations

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20230411057881N1
Enrollment
60
Registered
2023-05-21
Start date
2023-03-21
Completion date
Unknown
Last updated
2023-05-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dosimetry with and without chest phantom radiation shields and thorax phantom - examination of noise and average CT number in the CT scan phantom CTDI image with and without radiation shields - examination of artifacts in the chest CT scan image of female patients without and with the best shield.

Interventions

Intervention 1: Intervention group: 30 female patients aged 20-75 years, on whom we put the best radiation shield (suitable dose reduction and minimal noise on the image) during lung CT. Intervention

Sponsors

Semnan University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
Female
Age
20 Years to 75 Years

Inclusion criteria

Inclusion criteria: 20 to 75 years old woman subject to chest CT scan

Exclusion criteria

Exclusion criteria: A patient who has a reduced level of consciousness (as a result of trauma or stroke or...) the patient's lack of consent to continue participating in the research

Design outcomes

Primary

MeasureTime frame
Investigating noise and average CT number in CTDI phantom CT image with and without radiation protection. Timepoint: During 1months. Method of measurement: Using DICOM files software.;Chest and thorax phantom dosimetry with and without radiation shields. Timepoint: 2 months. Method of measurement: Using TLD dosimeter and RTI Piranha dosimeter.;Artifact examination in lung CT images of female patients without radiation protection and with the best protection (in terms of reducing the dose and creating the least noise on the image) is placed on their chest. Timepoint: 3 months. Method of measurement: Review of images by an experienced radiologist.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactMarziye Behmadi

Semnan University of Medical Sciences

behmadim@semums.ac.ir+98 23 3344 1022

Outcome results

None listed