The effect of Fresh Gas Flow on the speed of inhalational induction with sevoflurane. Other complications of anesthesia
Conditions
Interventions
Sponsors
Eligibility
Inclusion criteria
Inclusion criteria: Age between 6 month to 8 years candidate for elective orthopedic surgery having an indication for inhalational induction of anesthesia
Exclusion criteria
Exclusion criteria: lack of parental consent emergent surgery not being NPO significant cardiovascular disease pulmonary disease neurologic disorder prediction of a difficult airway or IV line facial or airway anomalies history of malignant hyperthermia in the patient or their family acute respiratory infection in the past week history of GERD
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Duration of reaching to the Bispectral Index between 60 to 70. Timepoint: from the start point of induction untill reaching to the Bispectral Index between 60 to 70. Method of measurement: using the bispectral index monitor based on electroencephalogram waves during anesthesia, measuring time in seconds.;Duration till the loss of response to squeezing the trapezius muscle. Timepoint: from the start point of induction to complete loss of response to squeezing the trapezius muscle. Method of measurement: measuring time in seconds, by physical examination and observing patient's reaction.;Duration until Laryngeal Mask Airway installation. Timepoint: from the start point of induction until Laryngeal Mask Airway installation. Method of measurement: measuring time in seconds.;Existence of reaction to Laryngeal Mask Airway installation. Timepoint: During Laryngeal Mask Airway insertion. Method of measurement: Observing the patient's reaction.;Heart rate. Timepoint: Immediately before induction and one minute after induction and during operation of the Laryngeal Mask Airway. Method of measurement: Beat Per minute using a non-invasive heart rate monitor.;Blood pressure. Timepoint: Immediately before induction and one minute after induction and during operation of the Laryngeal Mask Airway. Method of measurement: In millimeters of mercury using a non-invasive method of measuring blood pressure by monitoring device.;Oxygen saturation. Timepoint: Immediately before induction and one minute after induction and during operation of the Laryngeal Mask Airway. Method of measurement: in percent, by pulse oximeter device. | — |
Secondary
| Measure | Time frame |
|---|---|
| Breath holding. Timepoint: From the beginning of induction to the end of anesthesia. Method of measurement: observation.;Coughing. Timepoint: From the beginning of induction to the end of anesthesia. Method of measurement: observation.;Bradycardia. Timepoint: From the beginning of induction to the end of anesthesia. Method of measurement: Beat Per minute using a non-invasive heart rate monitor.;Low Blood pressure. Timepoint: From the beginning of induction to the end of anesthesia. Method of measurement: In millimeters of mercury using a non-invasive method of measuring blood pressure by device.;Laryngospasm. Timepoint: From the beginning of induction to the end of anesthesia. Method of measurement: observation.;Vomiting. Timepoint: From the beginning of induction to the end of anesthesia. Method of measurement: observation. | — |
Countries
Iran (Islamic Republic of)
Contacts
Tabriz University of Medical Sciences