Skip to content

Comparing the effectiveness of two types of suction on physiological indicators in infants

Effectiveness of premeasured minimally invasive endotracheal suction on physiological parameters in mechanically ventilated infants: a clinical trial study

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20200913048704N4
Enrollment
30
Registered
2024-05-03
Start date
2024-06-06
Completion date
Unknown
Last updated
2024-05-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Infants.

Interventions

Intervention 1: Intervention group: Group A, infants, if needed, will first receive tracheal tube suction in a pre-measured way for 12 hours. Before suctioning each baby, the stability of the baby's p

Sponsors

Babol University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All
Age
1 Days to 28 Days

Inclusion criteria

Inclusion criteria: Term infants who are connected to ventilators The stability of the physiological and clinical conditions of the infant They have not received surfactant in the last six hours

Exclusion criteria

Exclusion criteria: Critically ill infants who experience a severe drop in blood oxygen saturation during tracheal tube suction. If the infant is sent to another treatment center before completing the data. Changing the type of intra tracheal suction for any reason during hospitalization. Diagnosis of congenital heart disease, pulmonary disorders, etc. after entering the study.

Design outcomes

Primary

MeasureTime frame
Changes in blood oxygen saturation of infants before, during, and after tracheal tube suction in infants. Timepoint: One minute before, during, one, two and five minutes after tracheal tube suction. Method of measurement: Use of cardiopulmonary monitoring device.;Changes in heart rate of infants before, during, and after tracheal tube suction in infants. Timepoint: One minute before, during, one, two and five minutes after tracheal tube suction. Method of measurement: Use of cardiopulmonary monitoring device.;Changes in blood pressure of infants before, during, and after tracheal tube suction in infants. Timepoint: One minute before, during, one, two and five minutes after tracheal tube suction. Method of measurement: Use of cardiopulmonary monitoring device.

Secondary

MeasureTime frame
The number of times suction is needed. Timepoint: After any type of suction protocol. Method of measurement: Count the number of suction cases.;Number of cases of tracheal tube obstruction after each type of suction. Timepoint: After each type of suction. Method of measurement: Counting the number of cases of tracheal tube obstruction after each type of suction.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactAli Zabihi

Babol University of Medical Sciences

zabihi_alii@yahoo.com+98 11 3219 0795

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026