Condition 1: Tensile strength of absorbable Chromic gut suture. Condition 2: Tensile strength of absorbable polyglycolic acid suture.
Conditions
Interventions
Intervention 1: Intervention group: For one group is used chromic gut suture (under the brand name SUPA CHROMIC from Supa company, Iran). One section of each suture is cut off before suturing to per
Sponsors
Ahvaz University of Medical Sciences
Eligibility
Sex/Gender
All
Inclusion criteria
Inclusion criteria: Patients who need minor oral surgeries
Exclusion criteria
Exclusion criteria: Patients who do not return for removing sutures on days 7 and 10 after surgery
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Tensile strength of chromatic gut & polyglycolic acid sutures in Newton. Timepoint: On days 0, 7, 10. Method of measurement: Tensile strength is recorded by Universal testing machine (STM 50 machine from SANTAM Eng.Design.Co. Made in Iran). | — |
Countries
Iran (Islamic Republic of)
Contacts
Public ContactLeyla Golpasand Hagh
Ahvaz University of Medical Sciences
Outcome results