Comparison of effect of two different frequencies of Intra-aortic balloon pump on hemodynamic situation in patients after Coronary Artery Bypass Graft

Comparison of effect of 1:1 and 1:2 frequency of Intra-aortic balloon pump on hemodynamic situation in patients with medium dose of inotrope after Coronary Artery Bypass Graft

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20190922044844N1
Enrollment
9
Registered
2020-03-03
Start date
2019-10-07
Completion date
Unknown
Last updated
2020-03-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Influence of 1: 1 and 1: 2 frequency balloon pumps.

Interventions

This design is a quasi-experimental study of pre-test - posttest that compares all those who were at the 1: 1 frequency before and at the start of the intervention with the 1: 2 frequency step..

Sponsors

Esfahan University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: People who underwent CABG but due to low cardiac output, mean arterial blood pressure less than 80 mmHg failed to separate from the cardiopulmonary pump device and required postoperative IABP. Patients who are consenting to participate in the project, which will be obtained from the legal guardian if the patient is unconscious.

Exclusion criteria

Exclusion criteria: People who perform CABG at the same time as aortic valve and arch operations such as: aortic valve replacement, Bental surgery, etc.

Design outcomes

Primary

MeasureTime frame
The rate of change in the velocity time integral of aortic blood flow during systole. Timepoint: In average dose of Inotropes, this parameter is measured at 1:1 frequency,then the frequency is switched to 1:2 and after 20 minutes, it's measured at 1:2 frequency again. Method of measurement: The velocity time integral value of aortic blood flow during systole is measured by echocardiography.;The measurement of area left ventricular outflow tract ( area LVOT). Timepoint: At moderate doses of inotropic drugs, this variable is measured before the intervention begins. Method of measurement: This variable is measured by echocardiography,.;Rate of change in systolic blood pressure in patients. Timepoint: In average dose of Inotropes, this parameter is measured at 1:1 frequency,then the frequency is switched to 1:2 and after 20 minutes, it's measured at 1:2 frequency again. Method of measurement: it's measured by a built-in arterial line for patients and cardiac monitoring devise.;Rate of change in diastolic blood pressure in patients. Timepoint: In average dose of Inotropes, this parameter is measured at 1:1 frequency,then the frequency is switched to 1:2 and after 20 minutes, it's measured at 1:2 frequency again. Method of measurement: it's measured by a built-in arterial line for patients and cardiac monitoring devise.;Rate of change in heart rates in patients. Timepoint: In average dose of Inotropes, this parameter is measured at 1:1 frequency,then the frequency is switched to 1:2 and after 20 minutes, it's measured at 1:2 frequency again. Method of measurement: it's measured by a cardiac monitoring devise.;Rate of change in mean arterial blood pressure in patients. Timepoint: In average dose of Inotropes, this parameter is measured at 1:1 frequency,then the frequency is switched to 1:2 and after 20 minutes, it's measured at 1:2 frequency again. Method of measurement: it's measured by a built-in arterial line for patients and cardiac monitoring devise.;The measure of bo