Skip to content

Comparing Efficacy of Chest Tube drainage and Needle Aspiration for Pneumothorax Treatment in neonates

Comparison the efficacy and safety of needle aspiration and intercostals tube draining, in management of neonatal pneumothorax that receiving assisted ventilation

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20190810044491N1
Enrollment
116
Registered
2019-09-08
Start date
2019-02-20
Completion date
Unknown
Last updated
2019-10-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pneumothorax, Chest Tube, Needle Aspiration,. Pneumothorax

Interventions

Intervention 1: Intervention group (needle aspiration method): In this group (48 neonates), The thoracentesis was done by aspiration of air using a 10 to 20 cc syringes with a 23 to 25-gauge or 18 to

Sponsors

Iran University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All
Age
1 Days to 28 Days

Inclusion criteria

Inclusion criteria: Parent's consent to participate in the study Aged lower than 28 day Neonates with respiratory support (including endotracheal tube or CPAP or requires more than 40% oxygen) and chest pneumothorax were diagnosed by a physician who were hospitalized in NICU ward

Exclusion criteria

Exclusion criteria: No parent's consent Tension pneumothorax or emergency draining before x-ray Lung hypoplasia Congenital heart disease Meconium Aspiration Syndrome (MAS) Congenital Anomalies peters syndrome pleural effusion

Design outcomes

Primary

MeasureTime frame
Successful treatment rate. Timepoint: Before and after draining of pneumothorax. Method of measurement: X-ray and physical examination (neonatologist).

Secondary

MeasureTime frame
Complications related to the procedures (mortality rate, need for invasive and noninvasive ventilation, blood culture and CRP results, duration of antibiotic use and length of hospitalization, ). Timepoint: After draining of pneumothorax. Method of measurement: Physical examination and laboratory test.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactZinat Shakery

Iran University of Medical Sciences

zinatshakeri@yahoo.com+98 21 2304 6253

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026