Skip to content

The immediate effects of counterforce brace with and without vibration in participant with tennis elbow

The immediate effects of counterforce brace with and without vibration on pain, range of motion, grip strength and wrist extensor muscles strength in participant with tennis elbow

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20180619040148N3
Enrollment
27
Registered
2020-01-13
Start date
2019-12-22
Completion date
Unknown
Last updated
2020-02-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tennis elbow. Tennis elbow, Counterforce brace, Vibration, Lateral epicondilitis

Interventions

Intervention group: Brace counterforses, 5 minutes on the patient's hand, Location: 2.5 cm below the elbow. Intervention group II: Counterfeit brace with vibration, frequency 30-50 Hz, 2.5 mm amplitud

Sponsors

Iran University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All
Age
20 Years to 60 Years

Inclusion criteria

Inclusion criteria: People with tennis elbows according to the diagnosis of a specialist physician and standard diagnostic criteria Age 20 to 60 years old

Exclusion criteria

Exclusion criteria: History of surgery, cervical disc and elbow fracture Rheumatic diseases and peripheral neuropathy

Design outcomes

Primary

MeasureTime frame
Pain. Timepoint: Measurement of pain before intervention, after the first intervention and after the second intervention. Method of measurement: Visual analog scale and algometer for measuring pain.;Range of motion. Timepoint: Measurement of range of motion before intervention, after the first intervention and after the second intervention. Method of measurement: Goniometer for measuring range of motion.;Grip strength. Timepoint: Measurement of grip strength before intervention, after the first intervention and after the second intervention. Method of measurement: Dynamometer to measure grip strength.;Wrist extensor muscles strength. Timepoint: Measurement of strength of wrist extensor muscles before intervention, after the first intervention and after the second intervention. Method of measurement: Digital dynamometer for measuring the strength of wrist extensor muscles.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactMasumeh Bagherzadeh Cham

Iran University of Medical Sciences

BagherzadehCham.m@iums.ac.ir+98 21 8214 1612

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026