Skip to content

The effect lowering the dialysate temperature on hemodynamic indicators and dialysis efficiency of the diabetic patients

The study of effect lowering the dialysate temperature on hemodynamic indicators and dialysis efficiency of the diabetic patients in aliabn abitalb (AS) hospital of zahedan university of medical sciences in 2018

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20171009036675N2
Enrollment
32
Registered
2018-03-02
Start date
2018-01-21
Completion date
Unknown
Last updated
2018-03-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic kidney disease. Chronic kidney disease (CKD)

Interventions

Intervention group: In this study, 32 hemodialysis patients are selected availably and non-randomly, with inclusion criteria, who are referred to hemodialysis unit of Ali ebn Abitalib hospital in Zahe

Sponsors

Zahedan University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients should have a history of hemodialysis at least three months before the study Non-use of blood pressure reducing drugs is one of the inclusion criterias Patients should have less than 2 kg of weight gain during dialysis Patients who have experienced less than 90 mm Hg systolic pressure in previous sessions of dialysis and experienced related symptoms are included in the study. Patients should not have severe anemia (8Hb <) Patients should not have simultaneous malignancies Not having thyroid disorders is also one of the the inclusion criterias.

Exclusion criteria

Exclusion criteria: patient's death Incompatible dialysis with cold solution (in case of very severe chills). Consumption of food and fluids is higher than the amount prescribed during dialysis Unwillingness to continue participating in the study

Design outcomes

Primary

MeasureTime frame
Hemodynamic indicators. Timepoint: Before and after the intervention. Method of measurement: By thermometer and manometer.;Dialysis Efficiency. Timepoint: Before and after the intervention. Method of measurement: Based on the KT/V dialysis quality determination formula, more than 1.2 or less than 1.2.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactFatemeh Kiani

Zahedan University of Medical Sciences

f.kiani@zaums.ac.ir+98 54 3344 2481

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026