Effect of mechanical ventilation on intracranial pressure

Effect of airway pressure release ventilation on intracranial pressure and oxygenation of patients with traumatic brain injuries

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT2015070623104N1
Enrollment
40
Registered
2016-05-05
Start date
2015-07-23
Completion date
Unknown
Last updated
2018-02-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

traumatic brain injuries. Other intracranial injuries, Intracranial injury with prolonged coma,Traumatic subarachnoid haemorrhage,Traumatic subdural haemorrhage,Diffuse brain injury,Focal brain injury,Epidural haemorrhage,

Interventions

Intervention 1: Intervention of this research is a ventilation mode that is called Airway Pressure Release Ventilation that applied for half an hour. This is an inverse ratio mode that airway pressure
Intervention of this research is a ventilation mode that is called Airway Pressure Release Ventilation that applied for half an hour. This is an inverse ratio mode that airway pressure of patient, bet
In the control group patients are ventilated with SIMV mode for half an hour.

Sponsors

Mashhad University of Medical Sciences, research assisstance
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to 70 Years

Inclusion criteria

Inclusion criteria: Inclusion criteria: age between 18 and 70 years; traumatic brain injuries who are intubated and under mechanical ventilation with SIMV mode; stable hemodynamic (MAP more than 70 mm Hg for at least 30 minutes before the start of the study); Glasgow Coma Scale 10 mm Hg. Exclusion criteria: unstable hemodynamic (MAP 25 mmHg; pneumothorax

Exclusion criteria

Exclusion criteria:

Design outcomes

Primary

MeasureTime frame
Intracranial pressure. Timepoint: Before and half an hour after the intervention. Method of measurement: Intraventricular catheter -mmHg.;Pressure of arterial oxygen. Timepoint: Before and half an hour after the intervention. Method of measurement: mmHg.;Arterial oxygen saturation. Timepoint: Before and half an hour after the intervention. Method of measurement: Pulseoxymetry- percent.;Ratio of arterial oxygen to inspired oxygen fraction. Timepoint: Before and half an hour after the intervention. Method of measurement: number.

Secondary

MeasureTime frame
Mean arterial pressure. Timepoint: Before and after half an hour the intervention. Method of measurement: Barometer- mmHg.;Cerebral perfusion pressure. Timepoint: Before and after half an hour the intervention. Method of measurement: Calculation formula- mmHg.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactJavad Malekzadeh

Mashhad University of Medical Sciences

malekzadehj@mums.ac.ir+98 51 3859 5511