Skip to content

Orthotics in osteoprotic hyperkyphosis

The immediate effects of thoracolumbar back brace, plastic body jacket, and trunk corset on the balance of older people with osteoprotic hyperkyphosis

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20150210021034N7
Enrollment
20
Registered
2020-03-27
Start date
2017-12-22
Completion date
Unknown
Last updated
2020-04-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoporotic hyperkyphosis. Other secondary kyphosis, thoracolumbar region

Interventions

Intervention 1: Spinomed-designed orthosis
This orthosis includes a semi-rigid structure on the back and shoulder straps which fit the orthosis on the body. The back structure is formed on the spinal curve. Intervention 2: Flexible thoracolumb
This flexible corset has two posterior uprights to support the spine and anterior straps that fit the corset on the body. Intervention 3: Plastic body jacket
This is a rigid bi-valved orthosis that fits on the body and supports the spine. Intervention 4: Control group: No orthosis.

Sponsors

Esfahan University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All
Age
60 Years to No maximum

Inclusion criteria

Inclusion criteria: Having an osteoprotic hyperkyphosis Age over 60 years The history of two sudden falls in the last recent year Cognitive ability to give informed consent

Exclusion criteria

Exclusion criteria: Severe visual or vestibular dysfunction History of fracture or surgery in the spine

Design outcomes

Primary

MeasureTime frame
Postural stability. Timepoint: Before intervention and right away after receiving intervention. Method of measurement: Participants are asked to stand quiet on the force-plate while put the feet together and keep the arms relaxed beside the body. The center of pressure is recorded during 60 second of standing.;Timed get up and go. Timepoint: Before intervention and right away after receiving intervention. Method of measurement: Participants sit on a chair to start the test They are asked to walk with maximum speed during test. They rise with a "go" signal and walk until reach a line at 3 meters distance from the chair then turn and walk back to the chair and sit on it. The time is recorded using a stopwatch.;Forward reach distance. Timepoint: Before intervention and right away after receiving intervention. Method of measurement: Participants stand with feet together and raise the arm at their shoulder level then leaning forward as much as could with heels in contact with the ground. The anterior displacement of the hand is measured using a yardstick or tape.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactEbrahim Sadeghi-Demneh

Esfahan University of Medical Sciences

sadeghi@rehab.mui.ac.ir+98 31 3792 5235

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026