Skip to content

Comparison of the Hemodynamic Changes in Usage of Intratracheal Intubation and Laryngeal Mask in Patients under Anesthesia

Comparison of the Hemodynamic Changes in Usage of Direct Intratracheal Intubation and Laryngeal Mask in Patients under General Anesthesia

Status
Active, not recruiting
Phases
Phase 3
Study type
Interventional
Source
IRCT
Registry ID
IRCT2014110619037N3
Enrollment
200
Registered
2014-11-17
Start date
2013-10-23
Completion date
Unknown
Last updated
2018-02-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Condition 1: Heart rate instability due to intubation. Condition 2: Blood pressure instability due to intubation. - -

Interventions

Intervention 1: First intervention group: Using of intubation tube for direct intubation from SUPA company, Iran, registered No. 24422. Intervention 2: Second intervention group: Using of laryngeal ma
First intervention group: Using of intubation tube for direct intubation from SUPA company, Iran, registered No. 24422
Second intervention group: Using of laryngeal maskfor intubation from Cerdas Seimbang Sdn. Bhd. company, Malaysia, registered No. 130601

Sponsors

Investigator
Lead Sponsor

Eligibility

Sex/Gender
All
Age
20 Years to 50 Years

Inclusion criteria

Inclusion criteria: Inclusion criteria: Patients between 20 to 50 years of age who are candidate for surgery under general anesthesia and are in ASA class 1 (The American Society of Anesthesiologists Physical Status classification system): Normal healthy patients with no organic, physiologic, or psychiatric disturbance. Exclusion criteria: Patients who use anti-hypertensive, analgesic or sedative agents; patients who need urgent intubation; patients who are not NPO (nil per os); difficult intubation; diabetic patients.

Exclusion criteria

Exclusion criteria:

Design outcomes

Primary

MeasureTime frame
Mean heart rate. Timepoint: 1 minute before intubation and 1, 2, 3, 4, 5 and 10 minutes after intubation. Method of measurement: The monitor device.;Mean systolic blood pressure. Timepoint: 1 minute before intubation and 1, 2, 3, 4, 5 and 10 minutes after intubation. Method of measurement: The monitor device.;Mean diastolic blood pressure. Timepoint: 1 minute before intubation and 1, 2, 3, 4, 5 and 10 minutes after intubation. Method of measurement: The monitor device.;Mean arterial blood pressure. Timepoint: 1 minute before intubation and 1, 2, 3, 4, 5 and 10 minutes after intubation. Method of measurement: The monitor device.

Secondary

MeasureTime frame
-. Timepoint: -. Method of measurement: -.

Countries

Iran (Islamic Republic of)

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026