Skip to content

Effects of different tidal volumes on hemodynamic indices during deliberate hypotension by using nitroprosside & nitroglycerin

Comparative evaluation of effects of different tidal volumes of mechanical ventilation on hemodynamic indices during deliberate hypotension by using nitroprosside & nitroglycerine in ear microsurgery patients

Status
Active, not recruiting
Phases
Phase 2
Study type
Interventional
Source
IRCT
Registry ID
IRCT2014020516415N2
Enrollment
60
Registered
2014-07-14
Start date
2014-02-20
Completion date
Unknown
Last updated
2018-02-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Drug induced Hypotension. Hypotension due to drugs

Interventions

Intervention 1: First group: changing tidal volume between 5, 10 and 15 ml/kg during infusion of nitroglycerin. Nitroglycerin infusees in 0.5 mic/kg after induction of anesthesia and increase till 30%
Treatment - Drugs
First group: changing tidal volume between 5, 10 and 15 ml/kg during infusion of nitroglycerin. Nitroglycerin infusees in 0.5 mic/kg after induction of anesthesia and increase till 30% decrease in me
Second group: changing tidal volume between 5, 10 and 15 ml/kg during infusion of Na nitroprusside. Na Nitroprusside infusees in 1 mic/kg after induction of anesthesia and increase till 30% decrease

Sponsors

Isfahan University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Inclusion criteria: ASA 1 and 2; non smokers; no cardiopulmonary and renal disease; candidates for elective middle ear microsurgery. Exclusion criteria: Bleeding more than 2cc/kg; bronchospasm during surgery; need to other hypotensive drugs other than drugs of study.

Exclusion criteria

Exclusion criteria:

Design outcomes

Primary

MeasureTime frame
Heart rate, Blood pressure, Cardiac output, Stroke Volume. Timepoint: At the end of each tidal volume trial. Method of measurement: Measurement by anesthesia monitoring system and TECO (Trans Esophageal Cardiac Output measurement).

Secondary

MeasureTime frame
Peak airway pressure, Plateu airway pressure. Timepoint: At the end of each trial different tidal volumes. Method of measurement: By ventilator of anesthesia mashine.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactGolparvar M MD

Isfahan University of Medical Sciences

golparvar@med.mui.ac.ir+98 31 1624 9031

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026