Skip to content

Evaluation of efficiency of dialysis tube of thigh with different sizes

Evaluation of femoral tunnel hemodialysis catheter efficacy with different sizes

Status
Recruiting
Phases
Phase 3
Study type
Interventional
Source
IRCT
Registry ID
IRCT20130410012973N3
Enrollment
50
Registered
2019-05-13
Start date
2017-03-21
Completion date
Unknown
Last updated
2019-05-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

End stage renal disese. Unspecified kidney failure

Interventions

Intervention 1: Intervention group: We put in a group a 35 centimeter dialysis catheter in femur (Bared.co). Intervention 2: Intervention group: We put in a group a 42 centimeter dialysis catheter in

Sponsors

Arak University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Patients who cant put arteriovenous fistula or Jugular and subclavian catheters

Exclusion criteria

Exclusion criteria: The history of catheterization from femoral area or deep vein thrombosis in the lower extremity

Design outcomes

Primary

MeasureTime frame
Function and complication of different catheter. Timepoint: 1 and 3 and 6 months after insertion catheter. Method of measurement: Physical examination.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactAmirreza Naimi

Arak University of Medical Sciences

Amirrezanaimi@yahoo.com+98 86 3222 1041

Outcome results