Evaluation of internal jugular vein collapsibility index in three different of positive end expiratory pressure.
Conditions
Interventions
Intervention group: The patients will be placed on the ventilator under the following conditions. SIMV: TV= 8 cc/Kg, RR=10, PEEP=0, Fio2=50%. Then positive end expiratory pressure of ventilator will b
Sponsors
Zanjan University of Medical Sciences
Eligibility
Sex/Gender
All
Age
18 Years to No maximum
Inclusion criteria
Inclusion criteria: Age over 18 years
Exclusion criteria
Exclusion criteria: Cardiovascular and pulmonary diseases Sepsis Neck collar or neck dressing
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Internal jugular collapsibility index in positive end expiratory pressure of 0 cm H2O. Timepoint: 5 minutes after selecting the positive end expiratory pressure of 0 cm H2O. Method of measurement: ultrasound system (eZono 3000).;Internal jugular collapsibility index in positive end expiratory pressure of 5 cm H2O. Timepoint: 5 minutes after selecting the positive end expiratory pressure of 5 cm H2O. Method of measurement: ultrasound system (eZono 3000).;Internal jugular collapsibility index in positive end expiratory pressure of 10 cm H2O. Timepoint: 5 minutes after selecting the positive end expiratory pressure of 10 cm H2O. Method of measurement: ultrasound system (eZono 3000). | — |
Countries
Iran (Islamic Republic of)
Contacts
Public ContactHamid Kafili
Zanjan University of Medical Sciences
Outcome results
None listed