Skip to content

Evaluation of three different tidal volumes effect on internal jugular vein collapsibility index in hypovolemic mechanically ventilated patients

Evaluation of three different tidal volume effect on internal jugular vein collapsibility index to predict fluid responsiveness in hypovolemic mechanically ventilated patients in intensive care unit.

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
IRCT
Registry ID
IRCT20101211005363N11
Enrollment
30
Registered
2019-04-07
Start date
2018-07-23
Completion date
Unknown
Last updated
2019-04-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypovolemia. Hypovolemia

Interventions

Intervention group: The patients will be placed on the ventilator under the following conditions. SIMV: TV= 8 cc/Kg, RR=10, PEEP=5, Fio2=50%. Then tidal volume of ventilator will be changed to 10 and

Sponsors

Zanjan University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: Hypovolemic patients Age over 18 years

Exclusion criteria

Exclusion criteria: Cardiovascular and pulmonary diseases Sepsis Neck collar or neck dressing

Design outcomes

Primary

MeasureTime frame
Internal jugular collapsibility index in tidal volume of 8 cc per kg. Timepoint: 5 minutes after selecting the tidal volume of 8 cc per kilogram. Method of measurement: ultrasound system (eZono 3000).;Internal jugular collapsibility index in tidal volume of 10 cc per kg of weight. Timepoint: 5 minutes after selecting the tidal volume of 10 cc per kilogram. Method of measurement: ultrasound system (eZono 3000).;Internal jugular collapsibility index in tidal volume of 12 cc per kg. Timepoint: 5 minutes after selecting the tidal volume of 12 cc per kilogram. Method of measurement: ultrasound system (eZono 3000).;Internal jugular collapsibility index in tidal volume of 8 cc per kg after fluid therapy. Timepoint: 5 minutes after selecting the tidal volume of 8 cc per kilogram. Method of measurement: ultrasound system (eZono 3000).;Internal jugular collapsibility index in tidal volume of 10 cc per kg after fluid therapy. Timepoint: 5 minutes after selecting the tidal volume of 10 cc per kilogram. Method of measurement: ultrasound system (eZono 3000).;Internal jugular collapsibility index in tidal volume of 12 cc per kg after fluid therapy. Timepoint: 5 minutes after selecting the tidal volume of 12 cc per kilogram. Method of measurement: ultrasound system (eZono 3000).

Countries

Iran (Islamic Republic of)

Contacts

Public ContactFatemeh Safavi

Zanjan University of Medical Sciences

tnaghibi@zums.ac.ir+92 48 33131559

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026