Skip to content

The effect of Trinitroglycerine injection on angiographic complications

Comparison of nitroglycerine injection with placebo on angiographic complications in patients with suspected ischemic heart disease

Status
Active, not recruiting
Phases
Phase 2
Study type
Interventional
Source
IRCT
Registry ID
IRCT138901283733N1
Enrollment
223
Registered
2010-06-12
Start date
2005-05-10
Completion date
Unknown
Last updated
2018-02-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diseases of the circulatory system.

Interventions

Intervention 1: Injection of 5 micrograms TNG in 150 cc Mglomyn dye. Time: During angiography. Intervention 2: 150 cc Myglomyn dye was mixed with 5 micrograms strile water and was injectrd during angi
Prevention
Placebo
Injection of 5 micrograms TNG in 150 cc Mglomyn dye. Time: During angiography.
150 cc Myglomyn dye was mixed with 5 micrograms strile water and was injectrd during angiography.

Sponsors

Isfahan University of Medical Sciences
Lead Sponsor

Eligibility

Sex/Gender
All
Age
20 Years to 75 Years

Inclusion criteria

Inclusion criteria: Inclusion criteria: signing informed consent, age between 20 and 75 years, no drug addiction, lack of brain vascular disease and systolic blood pressure above 100 mmHg, candidates for angiography, hemodynamic stability, Exclusion criteria: history of heart disease, history of hypertension

Exclusion criteria

Exclusion criteria:

Design outcomes

Primary

MeasureTime frame
Nausea. Timepoint: during angiography. Method of measurement: patient observation and expression.;Coronary artery spasm. Timepoint: during angiography. Method of measurement: angiography film.;Chest pain. Timepoint: during angiography. Method of measurement: Pain by the patient during angiography is reported ECG changes in addition to rising or down piece ST.;Systolic and diastolic blood pressure. Timepoint: during angiography. Method of measurement: monitoring intravascular pressure device that was attached to the patient during angiography.;Brady arrhythmia. Timepoint: during angiography. Method of measurement: ECG monitoring during angiography.

Countries

Iran (Islamic Republic of)

Contacts

Public ContactDr Masoumeh Sadeghi

Isfahan Cardiovascular Research Center/Isfahan University of medical Science

sadeghimasoumeh@gmail.com+98 31 1335 9090

Outcome results

None listed

Source: IRCT (via WHO ICTRP) · Data processed: Feb 4, 2026