Skip to content

Evaluation of the correlation of plasma volume status (PVS) to the haemodynamic parameters of transpulmonary thermodilution with continuous pulse contour analysis (PiCCO). A retrospective data analysis.

Evaluation of the correlation of plasma volume status (PVS) to the haemodynamic parameters of transpulmonary thermodilution with continuous pulse contour analysis (PiCCO). A retrospective data analysis. - PVSvsPiCCO

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
DRKS
Registry ID
DRKS00035926
Enrollment
800
Registered
2025-01-17
Start date
2024-08-22
Completion date
Unknown
Last updated
2026-06-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patients requiring intensive care without precise reasons. All patients with extended haemodynamic monitoring by PiCCO are included.

Interventions

Group 1: Retrospective analysis of all patients from 01/2020 to 03/2024 who were treated in one of the anaesthesiologically managed intensive care units at Mainz University Hospital with extended haem

Sponsors

Universitätsmedizin Mainz, Klinik für Anästhesiologie, Studientzentrum Anästhesie
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: Period from 01/2020 to 03/2024

Exclusion criteria

Exclusion criteria: Incomplete data acquisition, acquisition of other haemodynamic parameters that were not recorded with PiCCO, Pre-existing atrial fibrillation, No invasive mechanical ventilation

Design outcomes

Primary

MeasureTime frame
Assessment of the correlation of the Plasma Volume Status values with the haemodynamic parameters of the PiCCO measurement (stroke volume variance, global end-diastolic volume). These values are recorded at every point in the calibration of the PiCCO system (usually every 8 hours or at shorter intervals if there is an acute change in the patient's condition). All data records of the intensive care stay from admission to discharge are recorded.

Secondary

MeasureTime frame
Assessment of plasma volume status values in the event of changes in stroke volume, cardiac index and lactate. Changes in PVS in the event of Hb-relevant haemorrhages. Change in PVS if renal replacement therapy is required.

Countries

Germany

Contacts

Public ContactKatharina Hentschel-Monteiro

Universitätsmedizin Mainz, Klinik für Anästhesiologie, Studienzentrum Anästhesie

katharina.hentschel@unimedizin-mainz.de06131 176755

Outcome results