K07.1
Conditions
Interventions
Group 1: Training with the BSSO (bilateral sagittal split osteotomy) 3D-printed model (1st run
approximately 15 minutes)
Group 2: Training with the BSSO (bilateral sagittal split osteotomy) 3D-printed model (2nd run
approximately 15 minutes directly following 1st run)
Sponsors
Klinik für Mund-, Kiefer- und Gesichtschirurgie, Uniklinik RWTH Aachen
Eligibility
Sex/Gender
All
Age
18 Years to No maximum
Inclusion criteria
Inclusion criteria: Dental students at RWTH Aachen University and physicians /dentists at the Department of Oral and Maxillofacial Surgery at University Hospital RWTH Aachen; consent to participate
Exclusion criteria
Exclusion criteria: Refusal of participation
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Does training the BSSO with a 3D-printed model lead to an improvement of surgical skills on a Global Rating Scale? (Measurement time point: after both runs based on video recording of the work area) | — |
Secondary
| Measure | Time frame |
|---|---|
| -What is the minimum distance in mm between the fracture gap and the inferior alveolar nerve on the 3D-printed model of the BSSO? -How often does a bad split (unfavourable fracture of the mandible) occur on the 3D-printed BSSO? -Does performing a BSSO on a realistic 3D-printed model 3D-printed model improves the understanding of this using a numerical rating scale (NRS)? -How is the model perceived visually, haptically and as practical, in terms of in relation to the preparation for an upcoming operation in terms of Likert questions? -Are there differences between students and doctors/dentists with regard to questions regarding the outcomes? | — |
Countries
Germany
Contacts
Public ContactAshkan Rashad
Klinik für Mund-, Kiefer- und Gesichtschirurgie des Universitätsklinikums Aachen
Outcome results
None listed